Metadata-Version: 2.4
Name: virtual_plc
Version: 0.7.0
Summary: Local Mitsubishi MC protocol PLC simulator with configurable response faults
Author: greatgc-flow
License-Expression: MIT
Project-URL: Homepage, https://github.com/greatgc-flow/VirtualPLC
Project-URL: Repository, https://github.com/greatgc-flow/VirtualPLC
Project-URL: Issues, https://github.com/greatgc-flow/VirtualPLC/issues
Keywords: plc,mitsubishi,mc-protocol,simulator,testing
Classifier: Development Status :: 4 - Beta
Classifier: Intended Audience :: Developers
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3 :: Only
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Programming Language :: Python :: 3.14
Classifier: Operating System :: OS Independent
Classifier: Topic :: Software Development :: Testing
Requires-Python: >=3.10
Description-Content-Type: text/markdown
License-File: LICENSE
Provides-Extra: dev
Requires-Dist: pytest; extra == "dev"
Provides-Extra: test
Requires-Dist: pytest; extra == "test"
Requires-Dist: pymcprotocol>=0.3.0; extra == "test"
Dynamic: license-file

# VirtualPLC

A local Mitsubishi MC protocol PLC simulator for client tests, with sparse
memory, CPU control and declarative faults. Python 3.10+, standard library only.

AI agents: run `virtual-plc guide` for a compact usage guide; use `--json` for data.

1E error codes and `OutOfRange`: [BEHAVIOR](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md#slmp-1e-transport-opt-in) and [memory API semantics](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md#lifecycle-snapshots-timers-and-routes); `compare_observations` / `observation_template`: [PHYSICAL_ORACLE](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/PHYSICAL_ORACLE.md).

## 30-second quickstart

Install with `pip install virtual-plc`, then choose a recipe:

<!-- guide:run -->
```text
virtual-plc --port 5000 --text-pad 0x20
virtual-plc --profile iQ-R --port 5001 --initial-state STOP
virtual-plc --init seed.json --fault-plan faults.json --dump-on-exit saved.json
```
<!-- /guide:run -->

The third recipe needs the JSON files shown below. From a checkout, install
with `python -m pip install -e .`. `python -m virtual_plc` is the equivalent
entry point. For more startup details, run `virtual-plc guide run`.

Install the tested upstream client with `pip install pymcprotocol==0.3.0`.
This exact version is the repository's compatibility oracle; the separate
[client compatibility matrix](docs/CLIENT_COMPATIBILITY.md) distinguishes it
from our unreleased `greatgc-flow/pymcprotocol` fork and unverified real-PLC
behavior:

```python
from pymcprotocol import Type3E

client = Type3E(plctype="Q")
client.connect("127.0.0.1", 5000)
try:
    client.batchwrite_wordunits("D0", [123, -45])
    assert client.batchread_wordunits("D0", 2) == [123, -45]
finally:
    client.close()
```

For the iQ-R recipe (`virtual-plc --profile iQ-R --port 5001 --initial-state STOP`):

```python
from pymcprotocol import Type3E

client = Type3E(plctype="iQ-R")
try:
    client.connect("127.0.0.1", 5001)
    assert client.batchread_wordunits("D0", 1) == [0]
finally:
    client.close()
```

Local-only binding is enforced by default in the CLI **and Python API**.
Passwords simulate PLC locking; there is no network authentication. Never
connect to real equipment or production networks. If an isolated test network
really needs a non-loopback listener, explicitly opt in and set an idle timeout:

```text
virtual-plc --host 0.0.0.0 --allow-nonlocal --idle-timeout 30 --max-clients 16
```

The non-local override is **not authentication**; use only on a trusted,
isolated test network. `max_clients` defaults to 64; excess connections are
closed without allocating workers. Embedded servers use
`Server(host="0.0.0.0", allow_nonlocal=True, idle_timeout=30, max_clients=16)`.
A non-loopback host without explicit permission (or without an idle timeout
when permitted) raises a configuration error before listening.

## Multiple TCP/UDP listeners

The legacy command `virtual-plc --port 5000` still opens **one TCP port**.
Repeat `--listen` to expose several ports on **one shared virtual PLC**:

```powershell
virtual-plc --listen tcp:5000 --listen tcp:5001 --listen udp:5000
```

Each endpoint shares memory, CPU state, authentication-simulation lock and
the request serialization lock. Different transports can reuse the same
numeric port (TCP/5000 and UDP/5000). For a completely independent virtual
PLC with different memory, start another process. `--listen` replaces the
legacy `--port` option and may not be combined with it; `--host` applies
to every endpoint.

The same topology is available to embedded Python programs:

```python
from virtual_plc import Server

with Server(listeners=[("tcp", 0), ("udp", 0)]) as plc:
    print(plc.addresses)  # [("tcp", host, assigned_port), ("udp", host, assigned_port)]
    # Use a TCP client or an MC request datagram to either bound address.
```

For UDP, send **exactly one complete 3E/4E binary or ASCII MC request frame**
per datagram; replies are datagrams sent back to the source IP/port. Invalid,
truncated, concatenated or over-8192-byte datagrams are silently dropped.
UDP is connectionless: no TCP stream reassembly, session/idle timeout, or
retransmission is provided. Use application-level timeouts/retries and keep
UDP packets small enough to avoid IP fragmentation. Stock `pymcprotocol`
client connections are TCP; UDP clients must use a datagram-capable client.
The TCP-oriented `--fault-plan` is rejected if any UDP listener is enabled,
rather than pretending its close/RST/partial-send actions work for UDP.
`--max-clients` limits TCP sessions only.

Nonlocal network binds continue to require `--allow-nonlocal` and
`--idle-timeout`; that timeout does **not** add UDP session semantics.
There is no authentication or UDP rate limiting. Run on loopback or on
an isolated, trusted **test** network only; never connect to production PLCs.

For local UDP diagnostics, see [UDP observability](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md#udp-observability-opt-in).

## UDP response faults (optional)

UDP listeners support the independent drop/delay plan; see [FAULTS](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/FAULTS.md#udp-datagram-response-faults-opt-in).

## Standalone UDP client example (source checkout)

The pinned `pymcprotocol==0.3.0` client uses TCP. For UDP, use the
stdlib-only, **loopback-only** (127.0.0.1 or `--host ::1`) [3E binary D0 reader](examples/udp_read_d0.py).
It sends exactly one complete request datagram and validates the sender,
frame header, length, status and word size; malformed replies fail closed.
No retry, authentication, physical PLC compatibility or nonlocal target.

```text
python -m virtual_plc --listen udp:5000
python examples/udp_read_d0.py 5000
```

Seed D0 via an `--init` JSON file if you want a nonzero response.
See [client compatibility](docs/CLIENT_COMPATIBILITY.md) for the distinction
between this raw UDP example and the tested TCP-only pinned client.

## CLI reference

Run `virtual-plc guide options` for the generated flag/default table, or `virtual-plc --help`; see `virtual-plc guide run` for quick-start flags. Long options must be spelled in full; abbreviations exit 2.

| Guide topic | Contents |
|---|---|
| `virtual-plc guide run` | Installation, startup and shutdown |
| `virtual-plc guide options` | All flags and defaults, generated from argparse |
| `virtual-plc guide client` | Client reads/writes, control and addressing |
| `virtual-plc guide profiles` | Generated command/frame/wire/profile/device matrix |
| `virtual-plc guide ethernet` | Hardware model settings, overrides and offline reference JSON |
| `virtual-plc guide embed` | Python API and pytest fixture |
| `virtual-plc guide faults` | Plan schema, actions and examples |
| `virtual-plc guide memory` | Seeding, snapshots, ranges and devices |
| `virtual-plc guide troubleshoot` | Symptoms and fixes |
| `virtual-plc guide divergences` | Simulator policies and unverified PLC behavior |

Every topic accepts `--json`.

## MELSEC iQ-F SLMP 1E mode (opt-in)

Enable with `--slmp-1e`; this selects a separate 1E-only parser on synthetic Q memory. See [BEHAVIOR](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md#slmp-1e-transport-opt-in) for command bounds, diagnostics, remote-control policy and error codes; this is not FX5 hardware parity.

## Offline physical-oracle preparation

For separately and manually captured read-only 1E 15H model and 16H loopback
responses, use `python -m virtual_plc.oracle plan`, `template`, and
`compare FILE --report REPORT.json`. This offline utility **never contacts
a PLC** and never certifies real hardware. See [offline oracle procedure](docs/PHYSICAL_ORACLE.md).

## FX5 vendor SLMP port preflight (offline reference)

Offline helper `inspect_reference_slmp_port(model, port)` checks vendor recommended and reserved port ranges; see `virtual-plc guide ethernet --json` and [FX5 port scope](docs/research/FX5_SLMP_PORT_SCOPE_20261031.md).

## RnCPU built-in service connection settings (offline reference)

Service-specific connection rules for RnCPU built-in Ethernet (auto-open UDP vs per-GOT TCP); see `virtual-plc guide ethernet --json` and [RnCPU service connection scope](docs/research/RNCPU_BUILTIN_SERVICE_CONNECTIONS_20261101.md).

## FX5 CPU firmware compatibility (offline reference)

Offline helper `inspect_reference_fx5_simple_cpu_communication(model, firmware)` checks model/firmware support gates; see `virtual-plc guide ethernet --json` and [FX5 firmware matrix](docs/research/FX5_CPU_FIRMWARE_SIMPLE_COMM_20261101.md).

## FX5-ENET existence-check settings (offline reference)

Offline helper `inspect_reference_fx5_enet_alive_timers()` validates module alive-check timer ranges; see `virtual-plc guide ethernet --json` and [FX5-ENET source matrix](docs/research/FX5_ENET_ALIVE_REFERENCE_20261101.md).

## GX Works2/3 model-specific Ethernet settings (opt-in)

GX Works2/3 is an editor, **not** the hardware identity. This source checkout
supports `qj71e71` (Q / GX Works2), `lj71e71` (L / GX Works2),
and `rj71en71` (iQ-R / GX Works3).
Factory defaults, validated JSON overrides and a nonbinding effective-settings
inspection are in the [Ethernet settings guide](docs/ETHERNET_MODEL_SETTINGS.md).
The [official-manual research matrix](docs/research/GXWORKS_ETHERNET_PARAMETERS_20261031.md)
documents model boundaries and unresolved physical fidelity.
See the [RnCPU/FX5 hardware gap matrix](docs/research/ETHERNET_HARDWARE_NEXT_20261031.md)
before using an unsupported model's defaults. The existing
`guide ethernet --json` exposes FX5 built-in, FX5-ENET and RnCPU built-in as
**reference-only, not runnable** hardware; unknown timer defaults remain unknown.

```powershell
# Inspect defaults and configurable ranges without listening:
virtual-plc --ethernet-model qj71e71 --show-effective-ethernet
virtual-plc --ethernet-model lj71e71 --show-effective-ethernet
virtual-plc --ethernet-model rj71en71 --show-effective-ethernet

# Load optional JSON changes, share PLC state across explicit TCP/UDP ports:
virtual-plc --ethernet-model qj71e71 --ethernet-config ethernet.json --listen tcp:5000 --listen udp:5000
virtual-plc guide ethernet --json
```

The hardware model automatically selects its matching wire profile in the CLI;
explicitly conflicting `--profile` values are errors. JSON overrides preserve
whether each key was explicitly specified, even if equal to its factory value.
Selecting a model simulates its binary/ASCII data-code setting and RUN-time
MC write permission. **Only those settings change runtime behavior**; module
TCP/IP retransmit, response monitoring and alive timers are explicitly marked
`reference_only`, not substituted for `--idle-timeout`. Legacy `--port 5000`
and Q behavior remain unchanged without a model selection. Independent PLCs
run in **separate OS processes**; all listeners within one process share the
same PLC state.

## Profiles, frames and encodings

Commands support 3E/4E and binary/ASCII on all profiles. Q, L, QnA and iQ-L
share a wire class; iQ-R uses different descriptors/subcommands. Client
`plctype` and server `--profile` must agree for iQ-R. Inspect
`virtual-plc guide profiles --json` for the current matrix and device kinds.

This local recipe covers every profile/frame/wire combination:

```python
from itertools import product
from pymcprotocol import Type3E, Type4E
from virtual_plc import Server

for profile in ("Q", "L", "QnA", "iQ-L", "iQ-R"):
    with Server(profile=profile) as server:
        for kind, wire in product((Type3E, Type4E), ("binary", "ascii")):
            client = kind(plctype=profile)
            client.setaccessopt(commtype=wire)
            client.connect(*server.address)
            try:
                client.batchwrite_wordunits("D0", [123])
                assert client.batchread_wordunits("D0", 1) == [123]
            finally:
                client.close()
```

## Memory seeding, snapshots and embedding

Save seed.json (decimal address keys, unsigned native point values):

```json
{"D": {"100": [1, 2, 3]}, "M": {"0": [1, 0, 1]}}
```

`--init` loads before listening; `--dump-on-exit` saves the same schema after
graceful shutdown. The snapshot is written to a same-directory temporary file,
flushed and atomically replaced on successful completion. A failed write leaves
an existing snapshot untouched; abrupt process or OS termination may still
prevent saving the latest state. Dumps preserve explicit zeros and include
SD203. Loads
validate the complete snapshot before overlaying data. See
`virtual-plc guide memory` for bounds, retention and device names.

Latch ranges are cleared by latchclear and preserved by remote_run(clear_mode=1).
SM and SD are never cleared; latchclear requires STOP.

```python
from virtual_plc import Server, Memory, FaultPlan, __version__

memory = Memory()
memory.load({"D": {"100": [1, 2, 3]}})
with Server(memory=memory, fault_plan=FaultPlan([])) as server:
    print(server.address, __version__)
    # Connect clients here. Context exit stops and joins workers.
snapshot = memory.dump()
```

Seed before start/context entry; dump after stop. Direct Memory calls are not
synchronized with requests. Use clients for live writes. Server construction
initializes SD203; CLI seeding runs afterward. Writing SD203 changes the word
without changing CPU state. For a pytest fixture, run `virtual-plc guide embed`.

## Response faults

Save faults.json and pass `--fault-plan faults.json`:

Minimal example:

```json
{"steps": [{"match": {"command": "0x0619"}, "action": {"type": "delay", "seconds": 0.02}}]}
```

See [FAULTS](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/FAULTS.md) for the contract.

## Troubleshooting

- Large reads: pinned upstream pymcprotocol 0.3.0 calls `recv(4096)` once. Split batches; the server's
  point limit is separate. A raw reader can follow response lengths.
- CPU names: default Q returns `"VirtualPLC-Q\x00\x00\x00\x00"`. The client
  retains NULs; `--text-pad 0x20` returns `"VirtualPLC-Q"`. Non-UTF-8 fill
  such as 0xFF causes client decoding failure.
- Reset requires STOP. On receive/status failure, the client waits about 1 s
  and reconnects. A normal reset keeps the connection open.
- With pinned upstream pymcprotocol 0.3.0, truncated or closed binary replies
  can look like status/value 0 because that client does not validate headers/lengths. This is not proof of success.
- Idle timeout is disabled by default; explicit timeouts close idle or
  incomplete connections. Reconnect afterward.

More fixes: `virtual-plc guide troubleshoot`. Protocol details:
[BEHAVIOR](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md).

## Known divergences from a real PLC

`virtual-plc guide divergences` (`DIVERGENCES` in `virtual_plc/guide.py`) is the canonical list of simulator policies and unverified PLC behavior; see [BEHAVIOR](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md) for wire protocol details.

## Repository safeguards and verified handoff

For the repository, use the
[branch/release gate checklist](docs/governance/BRANCH_RELEASE_GATES_20261102.md)
before configuring `main` protection or creating a `v*` tag.
The [handoff log](docs/HANDOFF.md) records current state and CI evidence
(older prompts under `docs/handoff/` are historical); fetch remote main first.
An active GitHub ruleset cannot be inferred from a successful CI run.

## Development and releases

```text
python -m pip install -e . -r requirements-dev.txt
python -m pytest -q
```

The dev extra installs pytest only. The test extra adds the compatible oracle
range declared in pyproject.toml. requirements-dev.txt is the only exact client
pin. Dependabot updates that file and pyproject; the coverage guard rejects
newly uncovered public methods, device constants and lookup-only names.

The [wheel hash](https://github.com/greatgc-flow/VirtualPLC/blob/main/tests/oracle_pin.txt)
is checked when a matching-version wheel is retained under .venv/oracle. A
bumped oracle skips only the stale artifact-hash check; the full suite and
coverage guard still run. Oracle watch installs the latest client and changes
only that run's local version expectation, without committing the change.

```text
python -m pip install build twine
python -m build
python -m twine check dist/*
```

CI tests Windows/Linux on Python 3.10–3.14 (plus one macOS job), runs the bundled
tests from the extracted sdist, and installs built wheels in clean
environments. Tags must match pyproject version and point at a commit whose
main CI succeeded; trusted publishing requires
the PyPI publisher and GitHub environment pypi to be configured.

See [DESIGN](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/DESIGN.md), [BEHAVIOR](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/BEHAVIOR.md) and [FAULTS](https://github.com/greatgc-flow/VirtualPLC/blob/main/docs/FAULTS.md).
Licensed under [MIT](https://github.com/greatgc-flow/VirtualPLC/blob/main/LICENSE).

### RnCPU built-in Ethernet remote RUN/STOP setting check (offline reference)

Offline helper `inspect_reference_rncpu_remote_opening()` checks vendor opening settings; see `virtual-plc guide ethernet --json` and [RnCPU opening guide](docs/research/RNCPU_REMOTE_OPENING_SAFETY_20261101.md).

### R04CPU built-in Ethernet A038H offline timer preflight

Offline helper `inspect_reference_rncpu_data_timers()` validates R04CPU timer references; see `virtual-plc guide ethernet --json` and [R04CPU timer guide](docs/research/RNCPU_R04CPU_A038H_DATA_TIMER_REFERENCE_20261101.md).

### R04CPU built-in Ethernet external-device settings (offline)

Offline helper `inspect_reference_rncpu_external_device()` checks user slot and port ranges; see `virtual-plc guide ethernet --json` and [R04CPU port matrix](docs/research/RNCPU_R04CPU_EXTERNAL_DEVICE_PORTS_20261101.md).

### R04CPU external-device multi-entry offline review

Offline helper `inspect_reference_rncpu_external_device_batch()` lints multiple configuration rows; see `virtual-plc guide ethernet --json` and [R04CPU batch lint guide](docs/research/RNCPU_R04CPU_BATCH_LINT_20261101.md).