Metadata-Version: 2.4
Name: espspapy
Version: 2.1.0
Summary: Wi-Fi enrollment (ESP-Touch) and local control of ESP modules
License-Expression: GPL-3.0-or-later
Keywords: esp,esptouch,async
Platform: any
Classifier: Programming Language :: Python
Classifier: Development Status :: 3 - Alpha
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.14
Classifier: Framework :: AsyncIO
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: System Administrators
Classifier: Topic :: Home Automation
Requires-Python: >=3.14.0
Description-Content-Type: text/markdown
License-File: LICENSE
Provides-Extra: dev
Requires-Dist: prek; extra == "dev"
Requires-Dist: ruff; extra == "dev"
Requires-Dist: mypy; extra == "dev"
Requires-Dist: pytest; extra == "dev"
Requires-Dist: pytest-asyncio; extra == "dev"
Dynamic: license-file

# espspapy

Unofficial asynchronous Python library, compatible with the **Intex PureSpa**
Wi-Fi models released before 2024: it enrolls their ESP module on the Wi-Fi
network (ESP-Touch v1) and drives it on the local network.

> [!NOTE]
> This project is not affiliated with or endorsed by Intex. Intex and PureSpa
> are trademarks of their owner, used only to indicate compatibility. Newer
> models use another protocol and are not supported.

> [!WARNING]
> Use at your own risk: the library drives a heater and pumps. It comes without
> any warranty (see the license); keep an eye on the device when automating it.

## Installation

```bash
pip install espspapy
```

Requires Python 3.14+.

## Usage

```python
import asyncio

from espspapy import Device, Spa, async_discover, async_pair


async def main() -> None:
    # Enroll a module in pairing mode on the Wi-Fi (ESP-Touch)
    result = await async_pair(
        ssid="MyWifi",  # 2.4 GHz network
        password="secret",
        bssid="00:00:1A:2B:3C:4D",  # 2.4 GHz access point to join
        # local_ip="192.168.1.10",  # optional: this host, detected by default
    )
    print(result.mac, result.ip)

    # Find the modules of the LAN
    for info in await async_discover():
        print(info.uid, info.ip)

    # Drive a module (persistent connection + heartbeat)
    async with Spa("192.168.1.10") as spa:
        print(await spa.async_identify())
        status = await spa.async_get_status()
        print(status.current_temperature, status.target_temperature)
        await spa.async_set_device(Device.BUBBLES, True)
        await spa.async_set_temperature(38)


asyncio.run(main())
```

### Pairing

1. Hold the C/F Wi-Fi button of the control panel for about 5 seconds, until
   the Wi-Fi light blinks quickly: the module stays in pairing mode for about
   one minute.
2. Run `async_pair()` (or `espspapy pair`) from a host on the 2.4 GHz network.
   The credentials are sent with ESP-Touch v1 in broadcast mode (multicast is
   not used).
3. Open a TCP connection to the module right after the pairing (`Spa(ip)`):
   without a client on port 8990, the module may drop off the network.

The TCP server accepts a single client: close the original mobile client
before driving the module, and the other way round.

### API

| Call                                                   | Description                                                                  |
| ------------------------------------------------------ | ---------------------------------------------------------------------------- |
| `async_pair(ssid, password, local_ip=None, *, bssid)`  | Wi-Fi pairing, returns `PairingResult(mac, ip)`                              |
| `get_local_ip()`                                       | IP address of this host on the LAN                                           |
| `get_current_bssid(interface=None)`                    | BSSID of the 2.4 GHz access point this host is on (Linux), else `None`       |
| `async_discover(timeout)`                              | LAN discovery, returns `list[SpaInfo]`                                       |
| `Spa(host).async_identify()`                           | `SpaInfo(uid, ip, dtype)`                                                    |
| `Spa(host).async_get_status()`                         | `SpaStatus`                                                                  |
| `Spa(host).async_set_device(device, on)`               | Switch `Device.POWER`, `FILTER`, `HEATER`, `JETS`, `BUBBLES`, `SANITIZER`    |
| `Spa(host).async_toggle(device)`                       | Raw toggle                                                                   |
| `Spa(host).async_set_temperature(value)`               | Target temperature, in the device unit (10-40 °C or 50-104 °F)               |
| `Spa(host).async_set_unit(fahrenheit)`                 | Switch the spa to °F or °C, keeping the target temperature                   |
| `Spa(host).async_send_frame(frame)`                    | Raw hex frame (checksum added)                                               |
| `Spa(host).async_heartbeat()`                          | Keep-alive, when `heartbeat_interval=None`                                   |
| `Spa(host).async_set_filter_timer(hours, delay)`       | Run the filter for `hours`, after `delay` (`timedelta`, default now)         |
| `Spa(host).async_set_heater_timer(hours, delay, temp)` | Heat for `hours` after `delay`, at `temp` (default: current target)          |
| `Spa(host).async_set_sanitizer_timer(hours, delay)`    | Run the sanitizer for `hours` after `delay` (untested on a device)           |
| `Spa(host).async_clear_timer(device)`                  | Clear the timers of `FILTER`, `HEATER` or `SANITIZER`                        |
| `Spa(host).scheduled_timers`                           | Slots sent by this client that have not ended (the spa does not report them) |
| `Spa(host).async_set_timers(device, slots)`            | Replace the timers of a device with a list of `TimerSlot`                    |
| `build_timer_frame(device, slots)`                     | Timer frame without checksum, `[]` clears the timers                         |

Exceptions derive from `SpaException`: `SpaConnectionError`,
`TimeoutExceededError`, `SpaNotRespondingError` (the Wi-Fi module answered but
not the controller board), `InvalidFrameError`, `CommandError`, `PairingError`.

Timers are one-shot, relative to the time of sending, like the control panel
(delayed start and duration). A new timer replaces the previous one of the same
device. The spa does not report a timer before it starts, so the client keeps
what it sent in `scheduled_timers`:

```python
from datetime import timedelta

from espspapy import Device

await spa.async_set_filter_timer(4)  # filter now, for 4 hours
await spa.async_set_heater_timer(3, delay=timedelta(hours=2))  # current target
await spa.async_set_heater_timer(1, timedelta(minutes=15), temperature=38)
print(spa.scheduled_timers)  # {Device.HEATER: (TimerSlot(start=…, duration=1, …),)}
await spa.async_clear_timer(Device.HEATER)
```

Several slots per device (up to 7) go through `async_set_timers()` with a list
of `TimerSlot(start, duration, temperature)`.

#### Control panel and library compared

The control panel only offers the values of the user manual. The library sends
the timer frames of the mobile app, which accept more: those extra values are
allowed by the frame format, but most were not tried on a device.

| Setting              | Control panel (user manual)                | Library (frame format)                            | Checked on a device                           |
| -------------------- | ------------------------------------------ | ------------------------------------------------- | --------------------------------------------- |
| Filter duration      | 2, 4 or 6 hours                            | 1 to 48 hours                                     | 2 hours                                       |
| Filter start         | now, then again every day at the same time | now or after a delay, once (no daily repeat)      | now                                           |
| Sanitizer duration   | 3, 5 or 8 hours                            | 1 to 48 hours                                     | 3 hours (status byte 13: `84`)                |
| Sanitizer start      | now                                        | now or after a delay                              | now                                           |
| Heater delayed start | 0 to 120 hours, in hours, heater off only  | to the minute, the slot ending within 7 days      | now and 15 minutes                            |
| Heater duration      | 0 to 48 hours, 0 = no end                  | 1 to 48 hours (no "no end")                       | 1 hour                                        |
| Heater temperature   | current target                             | any target in range, per slot                     | current target (28 °C)                        |
| Timers per device    | 1                                          | up to 7 slots                                     | 1                                             |
| Read back            | shown on the panel                         | not reported before the start: `scheduled_timers` | timers set on the panel: status bytes 9-14    |
| Clear                | panel buttons                              | `async_clear_timer()`                             | running: stops at once; pending: never starts |

Values outside the panel choices (a 3-hour filter, a 90-minute delay) are
therefore untested: check the result with `espspapy monitor` the first time.

### Command line

```bash
espspapy discover
espspapy pair --ssid MyWifi  # BSSID detected if this host is on 2.4 GHz Wi-Fi
espspapy pair --ssid MyWifi --bssid 00:00:1A:2B:3C:4D
espspapy status 192.168.1.10
espspapy monitor 192.168.1.10 --interval 10  # --changes: print only changes
espspapy bubbles 192.168.1.10 on
espspapy temp 192.168.1.10 38
espspapy unit 192.168.1.10 f  # or c
espspapy timer 192.168.1.10 filter --hours 4
espspapy timer 192.168.1.10 heater --hours 3 --in 120 --temp 38  # in 2 hours
espspapy timer 192.168.1.10 heater --clear
espspapy shell 192.168.1.10  # debug shell of the Wi-Fi module
espspapy --json status 192.168.1.10
```

## Protocol

| Port              | Protocol      | Use                                                        |
| ----------------- | ------------- | ---------------------------------------------------------- |
| 7001 →            | UDP broadcast | ESP-Touch v1 pairing (lengths of packets)                  |
| 18266 ←           | UDP           | Pairing answer: marker, MAC, IP                            |
| 10549 → / 10500 ← | UDP broadcast | Discovery (`spa_request`)                                  |
| 8990              | TCP           | JSON messages `{"data", "sid", "type"}`                    |
| 23                | TCP           | Debug shell of the firmware (e.g. `task-stats`), see below |

Message types: `0` heartbeat, `1` command, `2` status report, `3` identification,
`7` firmware version (answer in `data`, not used by this library).
Frames are hex strings followed by the checksum `255 - sum(bytes) % 255`.
The status request is `8888060FEE0F01DA`; the answer is `FFFF110F01…`:

| Byte  | Content                                                                            |
| ----- | ---------------------------------------------------------------------------------- |
| 5     | Devices: bit 0 power, 1 filter, 2 heater (enabled), 3 jets, 4 bubbles, 5 sanitizer |
| 6     | Flashing: bit 0 error code                                                         |
| 7     | Water temperature, or error code + 100 (E81…E99, 200 = END)                        |
| 9-10  | Heater delayed start: `80` when set, then coded like the filter timer (see below)  |
| 11    | Heater duration set (`00`: none, the heater then stays on), coded like byte 14     |
| 12-14 | Filter, sanitizer, heater timers (bit 7 active, see below)                         |
| 15    | Target temperature (10-40 °C or 50-104 °F)                                         |

Bit 2 means the heater function is enabled, not that the water is being
heated, and no byte says whether the heater element runs. With the heater
enabled, the frame reads `07` at 27 °C both for a 24 °C target (panel LED
green, idle) and for a 28 °C target (LED red, heating). The board measures
decimals: at 28 °C displayed for a 28 °C target, it kept heating for about an
hour, then the LED turned green, with the same frame. So `SpaStatus.heating` is
`True` below the target, `False` above it or with the heater off, and `None`
(unknown) when the water is displayed at the target. Bit 6, once assumed to
mean "temperature reached", was never seen set. The command set that the
Intex cloud served for this model (type 3, `TESPA02`: the six toggles,
`8888050F0C` for the target and `8888060FEE0F01` for the status) has no other
status request, so the heating state cannot be read another way. The mobile
app shows the red and green heater LEDs only for newer models with `A5…`
frames.

The spa has no unit command: it takes the unit of the target temperature it
receives, 10-40 in °C and 50-104 in °F, and then reports the water temperature
in that unit too. Sending 82 to a spa in °C (target 24 °C) switched it to °F
(water `52` = 82 °F, target `52`); sending 24 switched it back. The mobile app
switches the unit the same way, so `async_set_unit()` converts the current
target before sending it, rounded half up like the app: a 24 °C target became
75 °F, then 24 °C again.

The toggle and temperature frames belong to command set 1/3; other models may
use other frames. Switching the heater on also starts the filter (bits 1 and 2
set together), and switching it off stops both.

### Device behaviour

From the user manual of a 2024 model with the same control panel; older models
are expected to behave the same way, which is not confirmed.

| Code | Meaning                                                                    |
| ---- | -------------------------------------------------------------------------- |
| E81  | Transmission failure                                                       |
| E90  | No water flow                                                              |
| E91  | Low salt level                                                             |
| E92  | High salt level                                                            |
| E94  | Water temperature too low                                                  |
| E95  | Water temperature too high                                                 |
| E96  | System error                                                               |
| E97  | Dry-run protection                                                         |
| E99  | Broken water temperature sensor                                            |
| END  | After 72 hours of continuous heating, the pump goes to an extended standby |

- Timers set from the control panel: filter 2, 4 or 6 hours (the cycle restarts
  every day at the same time), sanitizer 3, 5 or 8 hours, heater start delay 0
  to 120 hours and heater duration 0 to 48 hours. The controller only counts
  down: it has no clock.
- Timer bytes 12-14 of the status: the filter set to 2, 4 and 6 hours from the
  control panel reads `82`, `86` and `8A`, as does a 2-hour filter frame sent by
  this library (`82`). The value drops by one every 30 minutes (4 hours set at
  15:40: `86`, then `85` at 16:10), so the library decodes the low 7 bits as
  `bits / 2 + 1` remaining hours. Whether the last hour runs after the byte is
  back to `80`, and the sanitizer byte, are not checked yet.
- Heater timer from the control panel: one button sets the delayed start, read
  in bytes 9-10 (2 and 3 hours read `80 02` and `80 04`, decoded as
  `value / 2 + 1` hours like the filter; 1 hour reads `00 00`, like no delay, so
  the last hour of a delay is not visible), another the duration, read in bytes 11
  and 14 before the start: 1, 3, 4 and 48 hours read `81`, `85`, `87` and `DF`,
  decoded as `(bits + 1) / 2` hours. A duration of 0 (`00`, `80`) keeps the
  heater on once started. The delayed start can only be set while the heater is
  off (LED green or red: the button does nothing). A 1-hour delay, invisible in
  the frame, still started the heater and the filter one hour later (byte 5
  `01` → `07`, bytes 9-14 unchanged): the board counts the delay itself. The
  countdown of a longer delay is not checked yet.
- Heater timer frame sent by this library (`8888280F0A`, built like the
  decompiled app): a slot starting now for 1 hour started the heater at once
  (the board answered with a status) and stopped it one hour later, while bytes
  11 and 14 read `00` and `80` all along. The control panel showed the
  remaining hour. A running timer reads one unit less than a pending one, so
  its last hour is not visible, like the last hour of a delay. A slot starting
  in 15 minutes started the heater 15 minutes later, with nothing visible
  before (status frame and control panel): slots sent this way are stored on
  the board and cannot be read back.
- Sanitizer timer frame (`8888280F0B`) for 3 hours, starting now: byte 5 went
  `01` → `23` (filter and sanitizer), byte 13 to `84` (coded like the filter),
  and the control panel showed 3 hours. Clearing it a few seconds later
  (`async_clear_timer`) stopped the sanitizer and the filter at once (byte 5
  `01`, byte 13 `80`); the board answered both frames with a status.
- A filter slot starting in 15 minutes, cleared 5 seconds after it was sent,
  never started (status read every minute for 24 minutes).
- Because of the power limit, only these combinations can run together: filter,
  heater and bubbles; filter, heater and jets; filter, bubbles, sanitizer and
  jets (without the heater).
- Jets and bubbles stop by themselves after 30 minutes.
- Frost protection: below 4 °C, the filter and the heater start until the water
  reaches 10 °C.
- The default target temperature is 20 °C.

### Timers

The module has no clock: the decompiled mobile client sends each timer list as
delays from the time of sending, and resends it after every change.
`Spa.async_set_timers()` sends one-shot slots of the filter, heater or
sanitizer; the layout below comes from the decompiled code, and only the
combined frame was seen in a capture. The board may apply a timer frame
without answering (the module then reports `timeout`), so the frame is sent
once, without retry, and the status is read afterwards. One-slot frames of the
filter, heater and sanitizer, starting now or after a delay, and clearing,
were tested on a device (see "Device behaviour" above); several slots per
device and the combined frame are still untested.

| Frame        | Content                                                                  |
| ------------ | ------------------------------------------------------------------------ |
| `8888280F09` | Filter timers                                                            |
| `8888280F0A` | Heater timers                                                            |
| `8888280F0B` | Sanitizer timers                                                         |
| `8888710F11` | The three lists (filter, heater, sanitizer), then the target temperature |

Each list is `55` (or `00` to clear it) followed by up to 7 slots of 5 bytes,
padded with zeros to 36 bytes; the frame ends with the checksum. A one-shot slot
is:

| Byte | Content                                                                   |
| ---- | ------------------------------------------------------------------------- |
| 1    | Hours before the start, modulo 24 (modulo 168 for a long slot)            |
| 2    | Minutes before the start, bit 7 set for a long slot (24 hours or more)    |
| 3    | Duration in hours                                                         |
| 4    | Day bit: `1 << (hours before the start + duration) // 24` (`// 168` long) |
| 5    | Target temperature in °C (heater only, `00` otherwise)                    |

The library accepts slots that end within 7 days and last 1 to 48 hours. Weekly
slots set bit 7 of the day byte and use a mask of the selected days; their
exact layout is not confirmed, so they are not supported. The combined frame is
not sent either.

### Network and security

- The module forwards every command to the control board over a single serial
  link: with another client connected (Home Assistant, the mobile app), answers
  often come back as `timeout` or `mcu_busy`.
- The debug shell on TCP port 23 is open without authentication: keep the
  module on a trusted network. `espspapy shell <host>` opens it. It runs on the
  module, not on the spa control board: `help`, `task-stats`,
  `run-time-stats`, `heap-trace`, `echo-parameters`, `echo-3-parameters`,
  `reboot` and `smartconfig` (reboots in pairing mode, the module leaves the
  Wi-Fi network). The CLI asks for confirmation before the last two.
- The module also connects to a cloud service
  (`intexapphub.azure-devices.net`, Azure IoT Hub). Local control does not need
  it, so it can be blocked with a DNS rewrite.

## Sources

- ESP-Touch v1: [EspressifApp/EsptouchForAndroid](https://github.com/EspressifApp/EsptouchForAndroid),
  [KurdyMalloy/EsptouchPython](https://github.com/KurdyMalloy/EsptouchPython),
  [AtharvSavarkar/ESPTouch-Python](https://github.com/AtharvSavarkar/ESPTouch-Python)
- Pairing procedure: [Home Assistant integration, issue #51](https://github.com/mathieu-mp/homeassistant-intex-spa/issues/51),
  [manufacturer FAQ](https://www.intexdevelopment.com/support/faqlist?catkey=306&lst_lang=2)
- TCP protocol, message type 7, debug shell, cloud service and captured
  schedule frame: [djo1338/intex-mqtt-bridge, PROTOCOL.md](https://github.com/djo1338/intex-mqtt-bridge/blob/main/docs/PROTOCOL.md)
  and [REVERSE-ENGINEERING.md](https://github.com/djo1338/intex-mqtt-bridge/blob/main/docs/REVERSE-ENGINEERING.md)
- Commands and status frame: [mathieu-mp/aio-intex-spa](https://github.com/mathieu-mp/aio-intex-spa),
  [Home Assistant community thread](https://community.home-assistant.io/t/intex-pure-spa-wifi-control/323591)
- Error codes, timer ranges, power limit and automatic stops:
  [user manual of a 2024 model (351IO), in French](https://www.irripiscine.fr/media/akeneo_connector/asset_files/N/o/Notice_258b.pdf)
- Off-state temperature value and heater/filter dependency:
  [adrianjagielak/homebridge-intex-plus](https://github.com/adrianjagielak/homebridge-intex-plus/blob/latest/src/spaAccessory.ts)
- Command set served by the Intex cloud for this model (type 3, `TESPA02`) and
  timer decoding (`bits / 2 + 1` hours, found independently):
  [TA2k/ioBroker.intex, main.js](https://github.com/TA2k/ioBroker.intex/blob/master/main.js)

## Interoperability

The vendor no longer provides a client for these modules. The protocol is
documented here for interoperability only, so that owners keep the use of their
hardware (article L122-6-1 of the French intellectual property code, article 6
of Directive 2009/24/EC).

- The library is an independent implementation: it contains no code from the
  original client, only the information needed to talk to the module (ports,
  frames, encodings).
- Neither the original client nor its decompiled code is distributed with this
  project, and none should be contributed.
- New features should preferably be validated with network captures of the
  original client (observation of its behaviour) rather than with decompiled
  code.

## Development

```bash
uv sync --extra dev
uv run prek run --all-files
uv run mypy espspapy tests
uv run pytest
```

To try timers on a device, set one with `espspapy timer` and follow the status
with `espspapy -v monitor`, which shows the raw timer bytes:

```bash
uv run espspapy timer 192.168.1.10 filter --hours 2
uv run espspapy -v monitor 192.168.1.10 --interval 60
uv run espspapy timer 192.168.1.10 filter --clear
```