CGH Tab
The CGH tab holds the calibration of the optical train: the numbers
that QHOT needs to compute a hologram that puts each trap where you
placed it in the camera image. Change a value by clicking on it,
typing the new value and pressing Return. The next hologram uses it.
If the traps are not where the markers say, check these numbers first,
and in particular the position of the optical axis.
QHOT saves the calibration when you quit and restores it when it
starts. File → Preferences → Save Settings saves it
at once, and Restore Settings goes back to what was saved.
Instrument
- wavelength
- Vacuum wavelength of the trapping laser [μm]
- n_m
- Refractive index of the medium
- magnification
- Magnification of the objective lens
- focallength
- Focal length of the tube lens [μm]
- camerapitch
- Center-to-center spacing of the pixels of the camera [μm]
- slmpitch
- Center-to-center spacing of the pixels of the SLM [μm]
- splay
- Correction for the spreading of the beam with depth. It has no
units: the distance of a trap from the optical axis is scaled by the
factor 1/(1 + splay · z), where z is the depth of
the trap from the focal plane.
SLM
- xs, ys
- Position of the optical axis in the plane of the hologram [phixels].
A phixel is a pixel of the SLM.
- phis
- Tilt of the SLM relative to the optical axis [degrees]
- scale
- Scale factor of the SLM. The pixels of the SLM have the effective
spacing slmpitch / scale at the pupil of the objective.
Camera
- xc, yc, zc
- Position of the optical axis in the camera image [pixels]. A trap
at a z equal to zc is in the focal plane.
- thetac
- Rotation of the camera relative to the SLM [degrees]