Metadata-Version: 2.4
Name: modbus-connector
Version: 0.9.0
Summary: PySide6 GUI for debugging Modbus buses and developing Modbus devices
Author: cramen
License: MIT
Project-URL: Homepage, https://github.com/cramen/modbus_connector
Project-URL: Repository, https://github.com/cramen/modbus_connector
Project-URL: Issues, https://github.com/cramen/modbus_connector/issues
Keywords: modbus,modbus-tcp,modbus-rtu,rs485,plc,scada,gui
Classifier: Environment :: MacOS X
Classifier: Environment :: Win32 (MS Windows)
Classifier: Environment :: X11 Applications
Classifier: Intended Audience :: Developers
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Topic :: System :: Hardware
Classifier: Topic :: Utilities
Requires-Python: >=3.11
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: pymodbus[serial]==3.6.9
Requires-Dist: PySide6
Requires-Dist: pyqtgraph
Requires-Dist: pyqtdarktheme
Provides-Extra: dev
Requires-Dist: pytest; extra == "dev"
Requires-Dist: pytest-asyncio; extra == "dev"
Requires-Dist: ruff; extra == "dev"
Provides-Extra: build
Requires-Dist: pyinstaller>=6; extra == "build"
Dynamic: license-file

# modbus_connector

<img src="https://raw.githubusercontent.com/cramen/modbus_connector/main/assets/icon.png" width="96" align="right" alt="Modbus Connector icon">

[Russian version: README_ru.md](https://github.com/cramen/modbus_connector/blob/main/README_ru.md)

**[Download ready-made builds for macOS / Windows / Linux → Releases](https://github.com/cramen/modbus_connector/releases)**

**[Watch the video presentation (1 min, Russian voice-over) → docs/presentation.mp4](https://github.com/cramen/modbus_connector/blob/main/docs/presentation.mp4)**

A PySide6 GUI application for debugging Modbus buses and developing Modbus
devices. Works with Modbus TCP and Modbus RTU via synchronous pymodbus clients;
all Modbus logic runs in a separate thread (QThread), so the GUI never freezes.

## Features

- Multiple simultaneous connections in tabs: each tab is an independent
  session with its own connection, register table, log and scanner. Settings
  for all tabs persist between launches in
  `~/.modbus_connector/settings.json` (old single-session settings files keep
  working), and can also be saved to / loaded from an arbitrary JSON file via
  the File menu.
- Connection types: TCP (host, port, timeout), RTU (serial port, baudrate,
  parity, etc.; RTU by default) and **RTU over TCP / RTU over UDP** for
  RS-485↔Ethernet converters — all configured in the GUI.
- Slave mode / device simulator (the **Mode** combo in each tab): the tab
  turns into a Modbus server — TCP, RTU or **RTU over TCP**, answering one
  unit id or **any** — with an editable register map. Set values manually in
  the row's display format (0.1 for f32, plain text for ascii/ascii1 — they
  land in the datastore instantly), watch master writes flash the table and
  every request and client connect hit the log, or drive rows with expression
  rules recomputed on a
  configurable tick (`[name]` references, `t` seconds since start, `prev`
  previous value, `rand()`/`randint(a,b)`). Device templates fill the map in
  one click — handy for debugging masters and gateways without real hardware.
- Device templates (the **Templates** menu): ready-made register maps and
  default connection settings for popular devices — Eastron SDM120/SDM630,
  EPEver Tracer-AN, Huawei SUN2000, Delta Electronics MS300/C2000 and
  16 Wiren Board devices (WB-MS/WB-MSW sensors, WB-M1W2, WB-MR6C/WB-MR2M/
  WB-MRWM2 relays, WB-MDM3/WB-MRGBW-D dimmers, WB-MAP3E/WB-MAP6S/WB-MAP12E
  energy meters, WB-MAI6/WB-MAI11/WB-MAO4 analog I/O, WB-MCM8, WB-MIR).
  Choosing a template opens a new tab
  with everything pre-filled — just press Connect.
- Register table: rows with a name, area type (coils, discrete inputs,
  holding/input registers), address and count; read and write values.
  Enter in the "New value" column sends the write command, Ctrl+R (Cmd+R on
  macOS) reads the current row; the whole table is keyboard-friendly.
- Rich value display: per-row formats (dec/hex/s16/u32/s32/f32/u64/s64/f64/
  ascii) with byte order variants (ABCD/CDAB/BADC/DCBA), scaling with offset
  and engineering units; a value that changed between reads flashes for a
  couple of seconds.
- Per-row Unit ID (rows can address different devices on the same bus) and
  per-row polling interval (slow and fast registers in one table).
- Live graphs ("Graph…" button, separate window): a trend sparkline per table
  row and a full plot window with multiple series, sliding-window/follow or
  manual zoom, and draggable markers with per-series min/max/avg.
- Background logging of polled values to a CSV or JSON Lines file ("Log to
  file" button), with a configurable set of fields.
- System/Light/Dark theme (pyqtdarktheme) from the View menu — graphs,
  sparklines, status colors and highlights all follow the theme.
- Filter box and one-click "Sort by address" for large tables. Table columns
  can be reordered by dragging the headers and shown/hidden via the header's
  right-click checklist; the layout persists between sessions.
- Per-row polling checkbox (leftmost column): unchecked rows are skipped by
  polling and "Read all" and are hidden from the graph window; manual reads
  and writes still work.
- Alarm rules ("Alarms…" button): per-row ordered rules (>, <, >=, <=, ==,
  !=, in/outside range — first match wins) highlight the value cell in red
  or yellow, write an event to the log and optionally play a siren sound
  when a rule starts matching (including escalation to a stricter rule).
- Snapshot diff ("Snapshot"/"Diff…" buttons): remember the current raw values
  of all rows, then compare them with later reads in a separate window —
  changed rows are highlighted, an "Only differences" filter hides the rest,
  and "Take new snapshot" accepts the current values as the new baseline.
- Expressions (the fx toolbar button): a block of computed rows under the
  table — "[name]" references a row's scaled value, arithmetic, pi/e and
  functions (abs, sqrt, sin, min, max, clamp, …) are allowed; each expression
  has a trend sparkline, joins the graph window as an "fx name" series, can
  carry alarm rules like a regular row, and offers autocompletion (register
  names and functions) while typing.
- Advanced protocol functions: Mask Write Register (0x16), Read/Write Multiple
  Registers (0x17), Read Device Identification (0x2B) and serial-line
  Diagnostics (0x08) — via dedicated dialogs.
- Link visibility: transaction statistics in the status bar (count, errors
  with percentage, top error kind, average response time), human-readable
  Modbus exception names and a live connection indicator (green = alive,
  orange "(idle)" = link idle or degraded).
- Address scanner ("Scanner…" button, separate window): iterates unit ids in
  a given range with configurable probes and shows devices that answered at
  least one probe; double-click a found unit to select it for the connection.
  A second sweep scans the register address space of a known unit and lists
  the addresses that respond — together with the read values decoded in
  several columns at once (Bool for coils/discrete inputs; dec, hex, s16,
  u32, s32, f32 and ascii for registers).
- Log panel at the bottom of the window, toggled with the "Log" button:
  human-readable requests/responses, optional raw bus traffic in hex
  ("Raw" checkbox) and export of the whole log to a file ("Save…").
- A help button (a "?" icon with a tooltip) in each window (table toolbar,
  graph, scanner) opens a short help sheet with that window's controls and
  hotkeys; window toolbars use compact icon buttons with tooltips.
- Bilingual UI: English and Русский, switched live in View → Language
  (default follows the system locale; the choice persists).

## Screenshots

Main window (light and dark themes — the View menu switches them) — two
connection tabs, register table with read values and per-row trend
sparklines, log:

![Main window, light theme](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/main_window.png)

![Main window, dark theme](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/main_window_dark.png)

Live graph — multiple series in a follow window, zoom and draggable markers
with per-series min/max/avg (the "Graph…" button in the connection panel);
light and dark themes:

![Live graph, light theme](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/graph_window.png)

![Live graph, dark theme](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/graph_window_dark.png)

Per-row display settings — Scale/Offset/Unit and a byte-order override per
register row (the "Display…" button above the table):

![Display settings](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/display_dialog.png)

CSV export — choose which columns to write and their order (the "CSV" button
above the table):

![CSV export](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/export_dialog.png)

CSV import — map file columns to register fields before loading the table:

![CSV import](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/import_dialog.png)

Logging to a file — write polled values to CSV or JSON Lines: file, format,
field selection and a per-row checklist (the gear icon next to "Log to file"):

![Logging settings](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/logging_dialog.png)

Address scanner — unit sweep with probes and the register address scan:

![Scanner](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/scanner.png)

Snapshot diff — capture the current values, read again later and compare;
changed rows are highlighted:

![Snapshot diff](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/snapshot_diff.png)

Expressions — computed rows over register values, with trend sparklines
(the fx toolbar button):

![Expressions](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/expressions.png)

Slave mode — the tab as a Modbus device emulator: server parameters and an
editable register map with manual values and expression rules (the "Mode"
combo above the table):

![Slave mode simulator](https://raw.githubusercontent.com/cramen/modbus_connector/main/docs/screenshots/simulator.png)

## Requirements

- Python 3.11+

Runtime dependencies (installed automatically by pip, see `pyproject.toml`):

- `PySide6` — Qt 6 GUI framework; the full meta-package including Addons
  (QtMultimedia is used for the alarm sound)
- `pymodbus[serial]==3.6.9` — Modbus TCP/RTU protocol stack (synchronous
  clients); the `serial` extra brings `pyserial` for RTU ports
- `pyqtgraph` — live register graphs (pulls in `numpy`)
- `pyqtdarktheme` — light/dark/system themes

Optional extras:

- `pip install -e .[dev]` — `pytest`, `pytest-asyncio`, `ruff` (tests & lint)
- `pip install -e .[build]` — `pyinstaller>=6` (standalone app bundles)

## Installation

```bash
python -m venv .venv
source .venv/bin/activate
pip install -e .[dev]
```

## Run

```bash
modbus-connector
# or
python -m modbus_connector
```

## Usage

### Connecting

1. Choose the connection type: **TCP** (host, port), **RTU** (serial port,
   baudrate, data bits, parity, stop bits — RTU is the default; use "Refresh"
   to rescan serial ports) or **RTU over TCP** / **RTU over UDP** (host, port —
   RTU frames inside a network socket, for RS-485↔Ethernet converters such as
   USR or Elfin).
2. Set the **Unit ID** of the target device (used for all register operations)
   and the response **Timeout**.
3. Press **Connect**. Input fields are locked while connected; press
   **Disconnect** to change settings.

The status label next to the button is live: green means the link is up,
orange with an "(idle)" suffix means the connection is configured but the last
transaction timed out — pymodbus reconnects transparently on the next request,
so this is informational, not an error. The status bar at the bottom of the
window shows transaction counters: total, errors with a percentage and the
most frequent error kind (the full breakdown by error type is in the label's
tooltip), plus the average response time of successful operations. Modbus
exception responses are reported by name (e.g. "Illegal Data Address (0x02)")
in the log.

### Working with tabs

The main window holds connections in tabs. The **+** button in the tab bar
corner opens another independent session — its own connection, register table,
log and scanner window. The tab title follows the connection (e.g. `tcp
192.168.1.10:502`); the last remaining tab cannot be closed. The status bar
statistics follow the active tab. All tabs are saved to the settings on exit
and restored on the next launch — including each table's column widths. The
**View** menu switches the theme (System/Light/Dark); the choice is app-wide
and is saved with the settings.

### Device templates

The **Templates** menu (between File and View) lists the bundled device
templates grouped by manufacturer. Choosing one opens a **new tab** with the
connection settings and the register table pre-filled from the template —
press **Connect** and read. The tab keeps the template's name until the
session connects.

To add your own template, drop a JSON file into
`src/modbus_connector/templates/<Manufacturer>/<Device>.json`:

```json
{
  "name": "My Device",
  "description": "optional text, shown as the menu item tooltip",
  "connection": {"type": "RTU", "rtu_baud": "9600", "unit": 1, "timeout": 3.0},
  "registers": [
    {"name": "Voltage", "kind": "input_registers", "address": 0, "count": 2,
     "format": "f32", "unit": "V"}
  ]
}
```

`connection` accepts the same keys as the saved settings (`type` — TCP/RTU/
RTU over TCP/RTU over UDP, `tcp_host`/`tcp_port` or `rtu_baud`/`rtu_bytesize`/
`rtu_parity`/`rtu_stopbits`, `unit`, `timeout`); each register row takes
`name`, `kind`, `address` (0-based PDU address), `count`, `format` and the
optional `order`, `scale`, `offset`, `unit` — the same fields as the table
columns. See any bundled file (e.g. `templates/Eastron/SDM120.json`) for a
full example.

### Adding registers

Press **Add register** and fill in the row: an arbitrary **Name**, the area
**Type** (coils, discrete inputs, holding registers, input registers),
**Address** (decimal or hex, e.g. `0x10`) and **Count** (how many values to
read starting at the address). The optional **Unit ID** column overrides the
connection-wide unit for this row (empty = use the connection unit) — handy
for polling several devices on one RS-485 bus. All columns are plain cells —
the table is fully navigable with the keyboard. The ✕ button deletes a row.

### Reading values

- **Ctrl+R** (**Cmd+R** on macOS) — reads the row that has the keyboard focus;
  **Ctrl+Shift+R** reads every row (the "Read all" button).
- Quick actions on the focused row (also in the table's right-click menu):
  **Ctrl+C** copies the value, **Ctrl+0**/**Ctrl+1** write 0/1,
  **Ctrl+=** (or numpad **Ctrl++**)/**Ctrl+-** step the last read value,
  **Ctrl+T** toggles it
  (coils flip the bit; a register goes 0↔1). Writes use raw values, so
  scaled/hex displays stay safe; input/discrete areas report "read-only".
- **Ctrl+Up**/**Ctrl+Down** move the selected rows as a block (multi-selection
  works); the row order persists with the session.
- **Read all** — reads every row once.
- **Start polling and record** — a split button: the main action reads all
  rows repeatedly with the interval set in the "Interval" field
  (milliseconds) and records value history; press **Stop polling** to stop.
  The dropdown offers **Start polling** (without recording) and **Start
  polling and record** — picking one while polling runs switches the
  recording mode on the fly, and the last choice becomes the main action.
  The optional **Poll, ms** column overrides the interval per row (empty =
  global interval; finer values are effectively clamped to the global tick).

Read values appear in the **Value** column; every request and response is also
shown in the log panel (toggled with the "Log" button). Bus-reading controls
(Read all, polling, logging, the 0x16/0x17 dialogs and the scanner's Start
buttons) are enabled only while a connection is up — dropping the connection
stops polling and logging.

### Display formats, scaling and units

For register rows the **Format** column chooses how the Value column renders:
`dec` (default), `hex` (`0xNNNN`), `s16` (signed 16-bit), `u32`/`s32`/`f32`
(pairs of registers as one 32-bit value), `u64`/`s64`/`f64` (groups of four
registers) and `ascii` (two characters per register, e.g. device names and
serial numbers; the string ends at the first NUL byte). Coils and discrete
inputs always show 0/1.

Multi-register values are big-endian by default (the first register is the
high word); the **Order** combo above the table sets the byte layout for all
rows (`ABCD` default, `CDAB` word-swapped, `BADC` byte-swapped words, `DCBA`
full reverse), and a per-row override is available in the **Display…** dialog.
A leftover register that does not fill a whole 32/64-bit group is shown as-is.

The **Scale**, **Offset**, **Unit** and per-row **Order** settings live in the
**Display…** dialog above the table (one row per register row). The raw
registers are first decoded according to Format and Order, then each decoded
number is displayed as `x * scale + offset` with the unit appended
(e.g. `23.5 °C`). Scaling is skipped for the `hex` and `ascii` formats.
Table columns can be resized by dragging the header separators.

A value that changed since the previous read flashes green for ~2 seconds.

Use the **Filter…** box above the table to show only rows whose name, type,
address or unit id contains the text, and **Sort by address** to reorder the
table by address.

### Writing values

Type the value(s) into the **New value** column and press **Enter** — the
write command is sent immediately. Values are always raw: display scaling
(Scale/Offset) is never applied to them.

- registers: decimal or hex numbers (`4321`, `0x10E1`); for Count > 1 enter
  several values separated by commas or spaces (`1, 2, 0xFF`) — a single value
  uses function "write single register", several values use "write multiple
  registers";
- coils: `0`/`1`, `true`/`false`, `on`/`off` (case-insensitive).

After a successful write the row is re-read automatically, so the **Value**
column reflects the applied change. Parse errors and Modbus errors are
reported in the log panel.

Note: only coils and holding registers are writable — discrete inputs and
input registers are read-only by the protocol.

### Advanced protocol functions

- **Mask write (0x16)…** (button above the table) — Mask Write Register:
  AND/OR masks applied to one holding register, setting or clearing individual
  bits without touching the others. Table rows covering the address are
  re-read after a successful write.
- **Read/Write (0x17)…** — Read/Write Multiple Registers: writes values and
  reads back a range in one atomic transaction (no race window); the returned
  values go to the log.
- **Device ID…** (connection panel, enabled while connected) — Read Device
  Identification (0x2B/0x0E): vendor name, product code, revision and other
  objects reported by the device.
- **Diagnostics…** (connection panel, enabled while connected) — serial-line
  diagnostics (0x08): loopback echo check and bus/slave message counters with
  Refresh and Clear counters. This is a serial-line function, but some TCP
  devices answer it too.

### Scanning for devices

Press **Scanner…** to open the scanner window. Set the unit id range
(default 1–247) and the probe list (register type + address + count to try on
each address; sensible defaults are prefilled). **Start scan** begins the
sweep, **Stop** aborts it; units that answered at least one probe appear in
the results list. **Double-click a found unit** to copy it into the connection
panel's Unit ID field. Scanning pauses polling in the main window.

The **Registers scan** section below works the other way around: for a known
unit it reads a range of addresses of a chosen register type one by one and
lists every address that answered as `0xNNNN (dec)` — a quick way to map the
register space of an unfamiliar device. **Add selected to table** turns the
checked addresses into register rows (all hits are checked by default;
duplicates are skipped), and **Device ID…** reads the selected unit's
identification (0x2B/0x0E).

The scanner's range, probe list and address-scan parameters persist in the
settings along with everything else.

### Graphs

Every register row captures its value history while polling runs in the
poll-and-record mode (scaled engineering value; hex/ascii rows are skipped)
and shows it as a small trend sparkline in the **Trend** column. The buffer
is bounded to ~10k samples per row; when recording is off, sparklines and
graph curves freeze on the last recorded data. **Graph…** (connection panel)
opens the full plot window:

- the **Series** checklist on the left picks which table rows are plotted
  (new rows join checked by default);
- **X scale: Follow** slides a window of the given width along the latest
  data, **Full** fits everything, **Manual** freezes the view — zooming or
  panning (wheel at cursor, left-drag, or the **Zoom rect** toggle) switches
  the mode to Manual so the change is visible; **Reset view** returns to
  Follow;
- **Markers** shows two draggable vertical lines (green A, red B) and a stats
  table with per-series min/max/avg between them plus Δt, updated live;
- hovering the plot shows a crosshair: a dashed vertical line at the cursor's
  time and a top-right readout with every series' value at that moment
  (nearest recorded sample, marked with a dot on each curve);
- **Clear** empties the recorded history and restarts the relative time
  axis (markers are re-placed once new data arrives); right-clicking a Trend
  cell in the table offers the same "Clear history";
- **Start polling and record** duplicates the table's poll control: starts
  polling with recording (or just enables recording if polling already runs),
  turns into **Stop polling** while recording is active.

Closing the graph window only hides it; the data stays.

### Logging values to a file

The **Log to file** button above the table writes every read value to a file
while it is on; starting it also starts polling if it wasn't running (with
history recording if the split button's mode is "and record"). The gear
button next to it opens the settings: the file (a timestamped name in the
home directory is suggested), the format, which optional fields —
timestamp (wall clock, ISO 8601 with milliseconds), row name, register
address and register type — accompany the value, and which table rows get
logged at all (the "Rows to log" checklist; new rows join logged by default,
and the per-row choice persists with the session). Values are
machine-friendly: decoded numbers with scale/offset but without the unit,
multi-value rows joined with ";", coils/discrete inputs as 0/1, hex/ascii
rows as displayed.

Formats: **CSV** (one row per read, a header row in new files) and **JSON
Lines** — one JSON object per line, which streams and appends cleanly.
Appending to an existing file is the default; the settings (not the on/off
state) persist with the session. Stopping logging leaves polling running.

### Log panel
The log panel at the bottom of the main window (toggled with the **Log**
button) shows every request and response with timestamps. The **Raw**
checkbox additionally displays raw bus frames in hex (`→ tx …` / `← rx …`) —
off by default to keep the log readable. **Save…** exports the entire log
(including raw frames hidden by the checkbox) to a text file; **Clear**
empties it.

### CSV import/export

The **CSV** drop-down above the table exchanges the register table with
spreadsheet tools:

- **Import table…** loads a CSV file and *replaces* the whole table. A
  mapping dialog appears first: every file column can be matched to a
  register field (name, kind, address, count, unit_id, poll_ms, format,
  scale, offset, unit, order) or skipped; matches are guessed from column
  names ("type" counts as kind) and the essential fields name/kind/address
  must be mapped. Errors are reported in the log, an invalid file leaves the
  table untouched.
- **Export…** opens a column chooser first — check which columns to write
  and reorder them (arrows/Space/Ctrl+Up/Ctrl+Down) — then writes the CSV:
  the chosen columns plus an optional `value` column with the currently
  displayed (formatted/scaled) text — readable as a report and re-importable:
  the `value` column is simply skipped by default in the mapping dialog, so
  the round trip "export → edit in Excel → import" works out of the box.

Only `name`, `kind` and `address` are required on import — unmapped optional
fields fall back to defaults. Files are written UTF-8 with BOM so Excel opens
them cleanly.


## Building a standalone executable

```bash
./build.sh        # macOS / Linux
build.bat         # Windows (cmd, also works by double-click)
```

The script installs PyInstaller (the `build` extra) and builds a standalone
application into `dist/`: on macOS — `ModbusConnector.app` plus a
`ModbusConnector.dmg` disk image; on Windows/Linux — a `ModbusConnector/`
folder with the executable inside (`ModbusConnector.exe` on Windows; copy the
whole folder to another machine). The artifact does not require Python on the
target machine.

macOS notes:

- Run: double-click `ModbusConnector.app` or `open dist/ModbusConnector.app`.
  Never run files from the intermediate `build/` directory (the script removes
  it after building).
- To move the app to another machine use the ready-made
  `dist/ModbusConnector.dmg` (do not rename or repack the `.app` into a `.pkg`
  yourself — such a file is not a valid installer).
- The app is ad-hoc signed: on another Mac Gatekeeper will warn about an
  unidentified developer on first launch — open via right-click → "Open", or
  remove the quarantine: `xattr -dr com.apple.quarantine ModbusConnector.app`.

Linux notes:

- RTU connections to serial ports (`/dev/ttyUSB*`, `/dev/ttyACM*`, etc.) require
  membership in the port's group, usually `dialout` (sometimes `uucp`). If you
  see `Errno 13` / "Permission denied" on connect, check the port:
  ```bash
  ls -l /dev/ttyUSB0
  ```
  Add your user to the group and re-login (or run `newgrp dialout`):
  ```bash
  sudo usermod -aG dialout $USER
  ```

## Project layout

```
src/modbus_connector/
  models.py       # Qt-free data types and helpers: TcpParams/RtuParams/
                  # RtuOverTcpParams/RtuOverUdpParams, RegisterRow, ScanProbe,
                  # DisplayFormat, ByteOrder, describe_connection(),
                  # parse_values()/format_values(),
                  # format_register_values()/format_scaled_values(),
                  # EXCEPTION_CODES/describe_exception(), Stats/StatsSnapshot
  backend.py      # ModbusBackend — synchronous pymodbus wrapper (no Qt):
                  # read/write, mask write (0x16), read/write registers (0x17),
                  # device identification (0x2B), diagnostics (0x08),
                  # unit scan, register address scan, raw traffic hook
  worker.py       # ModbusWorker (QObject) — signals/slots over backend, QThread;
                  # timing statistics, liveness checks, traffic forwarding
  sim_backend.py  # SimBackend — pymodbus Modbus slave server (TCP/RTU) for
                  # the slave mode: value blocks, master-write/request/client
                  # hooks
  sim_worker.py   # SimWorker (QObject) — signals/slots over SimBackend in a
                  # QThread; rule ticker for the simulator
  sim_panel.py    # slave-mode panel: server parameters, editable register
                  # map with manual values and expression rules
  connection_panel.py  # connection panel (TCP/RTU/RTU over TCP/RTU over UDP,
                       # state/set_state) with a live status indicator
                       # (gray/green/orange); Device ID…/Diagnostics… dialogs
  registers_panel.py   # register table: per-row unit/poll/format/order/scaling,
                       # change highlighting, filter/sort, Enter = write,
                       # Mask write…/Read/Write… dialogs, alarm rules,
                       # snapshot diff
  alarms_dialog.py     # per-row alarm rule editor (condition, color, log, sound)
  alarm_sound.py       # alarm siren: generated two-tone WAV + QSoundEffect
  snapshot_dialog.py   # non-modal window comparing a value snapshot with
                       # current reads (highlighted differences)
  scanner_panel.py     # unit scanner + register address scan (separate window)
  log_panel.py         # log panel (hideable): Raw hex traffic toggle, Save…
  settings_store.py    # settings persistence in ~/.modbus_connector/settings.json
  templates/      # bundled device templates: <Manufacturer>/<Device>.json
                  # register maps + default connection settings (package data,
                  # read via importlib.resources; loader in templates/__init__.py)
  session_widget.py # SessionWidget — one Modbus session (panels, scanner
                    # window, worker thread) as a self-contained widget
  main_window.py  # main window: sessions in tabs, File/Templates/View menus,
                  # status bar following the active tab
  app.py          # QApplication creation and startup
  __main__.py     # python -m modbus_connector
tests/
  conftest.py     # modbus_server fixture: test Modbus TCP server on 127.0.0.1
  test_models.py  # value parsing/formatting, exceptions, Stats
  test_backend.py # ModbusBackend against the test server
  test_registers_panel.py  # offscreen Qt tests for the register table
  test_session_widget.py   # session state round-trip and shutdown
  test_main_window_tabs.py # tab lifecycle and settings round-trip
```

## Development

```bash
pytest          # tests
ruff check .    # lint
```

The backend tests start a real Modbus TCP server (pymodbus) on 127.0.0.1
with a free port and exercise read/write/scan through `ModbusBackend`.

## CI

GitHub Actions (`.github/workflows/build.yml`) runs tests and builds artifacts
for all three OSes on macOS/Windows/Linux runners on every push to `main`:
`modbus-connector-macos` (DMG), `modbus-connector-windows` and
`modbus-connector-linux` (zip with the executable). Download them from the
workflow run page (Actions → a run → Artifacts; kept for 90 days); a build can
also be started manually via "Run workflow".

Pushing a `v*` tag (e.g. `git tag v0.1.0 && git push origin v0.1.0`)
automatically attaches the same files to a GitHub Release — a permanent
download page (Releases in the repository).