Setup
  instance splitter: a coupler: coupling 0.5
  instance combiner: a coupler: coupling 0.5
  instance upper: a waveguide: length 150 µm, loss 2 dB/cm
  instance lower: a waveguide: length 100 µm, loss 2 dB/cm
  ports: o1, o2, o3, o4
  the arms' guide: n_eff 2.35 and n_g 4.3 at 1.55 µm
  frequencies: Model A: 2001 from 187.5 to 200 THz; Model B: 201 over 193.72 THz ± 150 GHz; each fitted at the even-numbered and checked at the odd-numbered
  grid: none: the circuit's S-parameters, exact
  solver: vector fitting with real poles and conjugate pairs, the fewest poles whose error at the frequencies left out is below -60 dB
  tolerance: Model A within 1 pole of 67; Model B's 8 exactly

Ye et al.'s MZI (Photonics Res. 6, 560, 2018): ideal 50/50 couplers, arms of 150 and 100 µm, n_eff 2.35 and n_g 4.3 at 1.55 µm, 200 dB/m; a closed form, exact: no grid
  real poles and conjugate pairs, each fit checked at the frequencies between those it was fitted at; the target -60 dB in |ΔS|
  Model A, 187.5 to 200 THz, fitted at 1001 frequencies: 66 poles -68 dB, 64 poles -51 dB
  Model A, poles for −60 dB (pairs)     66.000000   paper 67         ± 1e0       ok
  Model B, 193.72 THz ± 150 GHz, fitted at 101 frequencies: 8 poles -99 dB, 6 poles -58 dB
  Model B, poles for −60 dB                     8   paper 8                      ok
all 2 within tolerance of the paper