Metadata-Version: 2.4
Name: xactflow-archidesc
Version: 0.3.1
Summary: XactFlow importer plugin that serializes an architecture description into an ipxact.Design.
Author: Maxime Travaillard
License-Expression: LGPL-3.0-only
Project-URL: Repository, https://github.com/IP-XACT/XactFlow-archidesc
Project-URL: Issues, https://github.com/IP-XACT/XactFlow-archidesc/issues
Keywords: IP-XACT,IEEE 1685,XML,Compiler,XactFlow,Architecture,Design,Importer
Classifier: Development Status :: 3 - Alpha
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3 :: Only
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Programming Language :: Python :: 3.14
Classifier: Topic :: Scientific/Engineering
Requires-Python: >=3.9
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: xactflow>=0.4.0
Requires-Dist: ipxact-compiler>=0.2.0
Provides-Extra: dev
Requires-Dist: pytest; extra == "dev"
Requires-Dist: mypy; extra == "dev"
Requires-Dist: xactflow-design>=0.2.1; extra == "dev"
Requires-Dist: xactflow-component>=0.2.1; extra == "dev"
Dynamic: license-file

# xactflow-archidesc

A [XactFlow](https://github.com/IP-XACT/XactFlow) importer plugin that turns a design described
in a Python script (which IPs it uses, how they are connected, and what the SoC offers to the
outside) into an `ipxact.Design` and the `ipxact.Component` containing it, built on
[`ipxact-compiler`](https://github.com/IP-XACT/ipxact-compiler)'s
[IEEE 1685-2022](https://standards.ieee.org/ieee/1685/10307/) object model.

IP-XACT `design` files are not made to be handwritten. With this package, a short script lists
the IP instances, the bus connections between them, any direct signal connections, and the
top-level ports and bus interfaces. The importer runs the script and adds the `Design` and the
`Component` containing it to a XactFlow `Library` as targets, for an exporter to write;
XactFlow's `link()` can check the design against the IP-XACT rules.

The full description of the format is in
[`doc/python-design-description.md`](doc/python-design-description.md). It describes the tool
as it is meant to work once finished, so the current version can differ from it in small ways.
The differences known today are listed in [Known limitations](#known-limitations).

## Installation

```bash
pip install xactflow-archidesc
```

For local development, `requirements-dev.txt` overrides `ipxact-compiler`, `xactflow` and
`xactflow-design` to local installations. It can be modified to adapt the paths or to keep any
of them on PyPI.

```bash
pip install -r requirements-dev.txt -e .
```

Requires Python >= 3.9.

## Usage

A design script builds a `Design` from an IP library and keeps it in a module-level variable
named `design`:

```python
from pathlib import Path

from xactflow import Library
from xactflow_archidesc import Design

library = Library.scan(Path(__file__).parent / "ip")
design = Design("example.org:soc:example:0.1", library)

cpu = design.add_ip("cpu", "example.org:ip:cpu:1.0", transforms=["tmrg"])
uart = design.add_ip("uart", "example.org:ip:uart:1.0", parameters={"BAUDRATE": 115200})
timer = design.add_ip("timer", "example.org:ip:timer:1.0")
debug = design.add_ip("debug", "example.org:ip:debug_module:1.0")
bus = design.add_ip("bus", "example.org:ip:interconnect:1.0")

design.connect_bus(cpu, bus)
design.connect_bus(bus.bus("m0"), uart, base_addr=0x4001_0000, size=0x1000)
design.connect_bus(bus, timer, base_addr=0x4002_0000, size=0x1000)

design.connect(debug.debug_req_o, cpu.debug_req_i)
design.connect(cpu.debug_resp_o, debug.debug_resp_i)

design.add_port("inout", "jtag_io", connect=debug.jtag_io)
design.add_port("out", "irq_o", connect=uart.irq_o)
```

`Design("example.org:soc:example:0.1", ...)` names the SoC: the component is
`example.org:soc:example.component:0.1` and the design `example.org:soc:example.design:0.1`.
The component's module is called `example`, or what `module_name=` gives, so an HDL
generator knows what to name it.

A runnable version of this script, with its IP library, is in
[`tests/fixtures/soc.py`](tests/fixtures/soc.py).

In short:

- `add_ip(name, vlnv, ...)` adds an IP instance, with optional `parameters` overrides and
  `transforms`.
- `connect_bus(a, b, ...)` connects a bus interface of `a` to one of `b`. It picks them by
  itself, or uses the one named with `instance.bus("name")`. `base_addr`/`size` place a target
  in the address map.
- `connect(source, target)` connects two ports. `instance.some_port` is short for
  `instance.port("some_port")`.
- `add_port(direction, name, width=None)` adds a top-level port, and
  `add_bus(name, bus_type, mode)` a top-level bus interface. `connect()` and `connect_bus()`
  connect them to the instances, or `connect=` does it right away. A top-level bus interface
  gets its ports from the internal interface it connects to, named `<bus>_<logical port>`.
- `connect_clk(source)` and `connect_rst(source)` connect a clock or a reset to every
  instance `in` port with the `isClock` or `isReset` qualifier that nothing drives yet. A
  top-level source gets the qualifier too.

Each call checks its arguments right away, so a mistake is reported on the line that made it.
All the details are in [the format description](doc/python-design-description.md#the-design-object).

Once installed, the importer registers itself under the `xactflow.importers` entry point group
as `archidesc`, so it runs as a XactFlow CLI command. With `xactflow-design` or
`xactflow-component` installed too, `--then` hands the library holding the design and the
component straight to that exporter. `--lib` adds IP-XACT folders to that library, for an
exporter that needs the instantiated components. To try it on the example of this repo,
create a virtual environment and install the package in it first. The `xactflow` command only
exists inside that environment, so activate it again in each new terminal:

```bash
python3 -m venv .venv && source .venv/bin/activate
pip install -e ".[dev]"
xactflow archidesc tests/fixtures/soc.py --lib tests/fixtures/library --then design --output out/
```

This writes `out/example.org_soc_example.design_0.1.xml`, named after the design's VLNV;
`--then component` writes the component, `out/example.org_soc_example.component_0.1.xml`. Both
are regenerated on every run: if `out/` is also given with `--lib`, the new documents replace
the ones read from there instead of being reported as duplicate VLNVs.

Or as a library, for example to link the design first:

```python
from pathlib import Path

import ipxact
from xactflow import Library, link
from xactflow_archidesc import ArchiDescImporter
from xactflow_component import ComponentExporter
from xactflow_design import DesignExporter

library = Library.scan("ip")
ArchiDescImporter().import_(Path("soc.py"), library)
[design] = library.targets(ipxact.Design)
linked = link(design, library)    # finds the component containing the design in the library
DesignExporter().export(library, Path("out"))
ComponentExporter().export(library, Path("out"))
```

The script runs like `python soc.py` would: a helper module next to it can be imported, and a
relative path in it is read from the current folder. Helper modules are forgotten once the
script has run, so scripts in different folders can each have their own `helpers.py`.
`Path(__file__).parent` gives paths that do not depend on where the command is run from. The
importer takes no options.

## Design notes

- **Vendor extensions.** Two things this format records have no place in IP-XACT, so they are
  written as vendor extensions in the `https://github.com/IP-XACT/XactFlow` namespace:
  `<xactflow:transforms>` on a component instance, listing the transformations in order, and
  `<xactflow:addressMapping baseAddr="..." size="..."/>` on the target side of a bus
  connection (a target or mirrored initiator interface).
- **Transformations are not applied here.** A separate tool, a transformer, reads
  `<xactflow:transforms>`, applies the transformations and returns the changed `Design`.
- **Parameter overrides follow the standard.** Only a parameter with a `parameterId` and
  `resolve="user"` can be overridden. The standard says an `immediate` parameter (the default)
  cannot be changed through configuration.
- **Connection names are unique.** A bus connection is named `<a>_to_<b>` and a port connection
  `<instance>_<port>_to_<instance>_<port>`, a top-level port or bus interface standing for
  itself by its name alone. A number is added when a name is already taken, by any kind of
  connection.
- **Top-level IOs.** The component containing the design has one view, `hierarchical`, whose
  `designInstantiation` refers to the design: that is how `link()` finds it. Its
  `componentInstantiation` gives the `moduleName`. A top-level port
  is reached with an `externalPortReference` and connects to an instance port of the same
  direction; a top-level bus interface is reached with a `hierInterface` and connects to an
  instance interface of the same mode, as the standard requires (SCR 2.4 to 2.10).
- **Monitors.** Connecting a monitor interface adds a `monitorInterconnection`. The interface it
  watches stays free for a normal connection.

## Known limitations

- `connect_bus` compares the bus definitions of the two interfaces, but not the parameter
  values set on the bus type (a data width, for example). Comparing them needs XactFlow to
  evaluate those values first. This should be changed in a future update.
- XactFlow's `link()` does not use the parameter overrides from `add_ip` yet. They are
  written to the design and exported, but not applied during linking.
- `connect` checks direction only for wire ports. Two transactional or two structured ports
  are connected with no further check, only a mix of the two kinds is refused.
- `connect` does not compare port widths, between instance ports or with a top-level port.
- `connect_rst` ignores the reset level (`isReset level="low"` or `"high"`): the source and
  the reset ports it connects are considered active at the same level.
- A top-level bus interface copies whole internal ports. A port map onto part of a port (a
  `partSelect` or sub-port) is refused, and a copied port keeps its width as written, even
  when it refers to a parameter of the internal component.
- A design describes one level only. Hierarchical designs, a real address mapping (instead of
  the `addressMapping` placeholder) and protocol bridges are not handled yet, see the open
  questions at the end of [the format description](doc/python-design-description.md).

## Development

```bash
python3 -m venv .venv
source .venv/bin/activate
pip install -r requirements-dev.txt -e .
pytest
mypy src
```

The tests use a small IP library in `tests/fixtures/library`. `tests/test_end_to_end.py` runs
the example script through the importer, links the result, exports it with
`xactflow-design` and reads the file back. `mypy src` checks the type hints, since the
package ships `py.typed`. CI runs both.

## License

LGPL-3.0. See [LICENSE](LICENSE).