Metadata-Version: 2.4
Name: openmhp
Version: 0.10.0
Summary: OpenMHP: reference implementation of the Open Model Hardware Protocol (MHP), an open protocol for AI agents to operate physical devices safely.
Author-email: Kushal Sinha <kushal.sinha@kortana.io>
License: Apache-2.0
Project-URL: Homepage, https://openmhp.com
Project-URL: Repository, https://github.com/kushalsinha/openmhp
Project-URL: Documentation, https://openmhp.com
Project-URL: Issues, https://github.com/kushalsinha/openmhp/issues
Keywords: mcp,agents,laboratory,instruments,hardware,robotics,automation,openmhp
Classifier: Development Status :: 3 - Alpha
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: Science/Research
Classifier: License :: OSI Approved :: Apache Software License
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Topic :: Scientific/Engineering
Classifier: Topic :: System :: Hardware
Requires-Python: >=3.10
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: pyyaml>=6
Provides-Extra: discovery
Requires-Dist: zeroconf>=0.130; extra == "discovery"
Provides-Extra: serial
Requires-Dist: pyserial>=3.5; extra == "serial"
Provides-Extra: mqtt
Requires-Dist: paho-mqtt>=2; extra == "mqtt"
Provides-Extra: node
Requires-Dist: zeroconf>=0.130; extra == "node"
Requires-Dist: pyserial>=3.5; extra == "node"
Requires-Dist: paho-mqtt>=2; extra == "node"
Provides-Extra: all
Requires-Dist: zeroconf>=0.130; extra == "all"
Requires-Dist: pyserial>=3.5; extra == "all"
Requires-Dist: paho-mqtt>=2; extra == "all"
Dynamic: license-file

<div align="center">

<picture>
  <source media="(prefers-color-scheme: dark)" srcset="assets/hero-dark.svg">
  <img src="assets/hero.svg" alt="OpenMHP" width="480">
</picture>

### Give AI agents a safe, shared interface to physical devices

OpenMHP is an open protocol for discovering, understanding, and operating lab instruments,
robots, and industrial equipment. MCP connects an agent to a software tool for a request and
response. OpenMHP extends that model for physical work that may run for minutes, hours, or days.

[![npm](https://img.shields.io/npm/v/openmhp-cli?label=openmhp-cli&color=3FB59A)](https://www.npmjs.com/package/openmhp-cli)
[![PyPI](https://img.shields.io/pypi/v/openmhp?label=openmhp&color=3FB59A)](https://pypi.org/project/openmhp/)
[![license](https://img.shields.io/badge/license-Apache%202.0-1f1f1f.svg)](LICENSE)
[![docs](https://img.shields.io/badge/docs-openmhp.com-2B8F78)](https://openmhp.com)

[Quickstart](https://openmhp.com/quickstart) · [Design](https://openmhp.com/design) · [Architecture](https://openmhp.com/architecture) · [Roadmap](https://openmhp.com/roadmap) · [Specification](SPEC.md) · [Contributing](CONTRIBUTING.md)

</div>

> **MCP calls a tool. OpenMHP stays with the machine.**
>
> An OpenMHP operation acquires a lease on the device, starts a durable job, and listens for
> telemetry, progress, results, and safety events until the work is complete. The agent can
> leave and return without losing the state of the physical process.

```text
MCP:      request ──────────────────────────────────────────────► response
OpenMHP:  lease ─► job ─► live telemetry and events ─► result ─► release
```

![AI agents connect through MCP and OpenMHP to physical devices such as lab instruments, robots and existing control stacks (OPC UA, ROS 2, SiLA 2, MADSci, PyLabRobot, MQTT), with safety enforced at the device and live telemetry flowing back. A dashed line marks the lab firewall: lab PCs dial out through it, nothing is opened inbound.](assets/openmhp-overview.svg)

## Why OpenMHP?

Connecting an AI agent to a database or ticketing system is mostly an API problem: send a
request and receive data. Connecting one to a centrifuge, robot arm, microscope, or PLC is a
long-horizon coordination problem:

- physical work lasts minutes or hours, well beyond one tool call;
- instruments produce telemetry, progress, files, and safety events while they run;
- the useful operating knowledge lives in manuals, SOPs, and experienced operators;
- a malformed request can waste a sample or move real hardware; and
- every vendor exposes a different control surface.

OpenMHP gives these devices a common agent-facing layer without replacing the control systems
already underneath them. The job records what the instrument is doing, the lease prevents a
second agent from interleaving commands, and the event stream keeps the agent informed without
making it continuously poll the device.

The design follows a few rules:

- **Use jobs for long-running work.** An action returns immediately; progress, results, and
  files remain available even if the agent leaves and comes back.
- **Push observations.** Signal changes, job progress, completion, and safety events flow back
  to the bridge rather than forcing the agent into a polling loop.
- **Load context progressively.** Agents first see a small card, then instructions and exact
  capabilities only for the device they select.
- **Keep safety at the edge.** The server beside the instrument checks state, approvals,
  interlocks, typed parameters, leases, and busy state before calling vendor code.
- **Wrap what the lab already has.** OpenMHP is an agent-facing layer over existing drivers and
  control systems such as OPC UA, ROS 2, SiLA 2, MADSci, PyLabRobot, and MQTT. It preserves
  those investments instead of replacing them.

An agent may propose an action. The device server decides whether it is allowed to run.
OpenMHP complements hardwired e-stops, light curtains, PLC safety logic, and normal lab
procedures; it does not replace them.

## Try it in five minutes

You need Node.js 18+ and Python 3.10+.

### 1. Install OpenMHP

Open Claude Code or Codex and ask your agent:

```text
Install OpenMHP for me by running `npx openmhp-cli setup`, then tell me when it is ready.
```

The agent will run:

```bash
npx openmhp-cli setup
```

The launcher installs an isolated runtime under `~/.openmhp`, installs the bundled Agent
Skills, and registers the MCP server with Claude Code and Codex. Restart the agent after setup
if it does not immediately show the OpenMHP tools.

For another MCP client, use:

```json
{
  "mcpServers": {
    "openmhp": {
      "command": "npx",
      "args": ["-y", "openmhp-cli"]
    }
  }
}
```

Prefer Python directly? Install the runtime with:

```bash
pip install "openmhp[all]"
```

### 2. Add the simulated lab

```bash
npx openmhp-cli demo
npx openmhp-cli list
```

This adds a simulated thermocycler and plate-handling arm. They use the same discovery,
description, safety, job, and event paths as real devices.

### 3. Ask your agent to do something concrete

```text
Find a thermocycler, show me its operating instructions, and rehearse a
3-cycle PCR at 95/58/72 °C before running it.
```

The normal operating loop is:

1. **Find** a suitable device from a plain-language request.
2. **Describe** it and read the owner's operating procedure.
3. **Check** live signals and interlocks.
4. **Plan** or dry-run the procedure through its safety gates.
5. **Run** it as a job and follow progress or pushed events.
6. **Verify** the result from measurements, not from the requested setpoint.

Try asking for a 200 °C thermocycler setpoint. The driver should refuse it and return the
allowed range.

## What using it looks like

Talk to the agent in terms of the work you want done:

| You ask | OpenMHP does |
|---|---|
| “Find the instruments on my network.” | Scans mDNS and known hosts for OpenMHP devices and returns compact device cards. |
| “Onboard my hotplate.” | Interviews the owner, writes and validates a device package, and produces a safety card for review. |
| “Run a 30-cycle PCR and hold at 4 °C.” | Finds a compatible device or recipe, rehearses the procedure, runs it as a job, and reports measured results. |
| “Watch the incubator overnight.” | Runs a background monitor and stores readings and alerts with the run. |
| “Which GC method should I use for ethanol?” | Searches versioned methods associated with the device and project. |
| “Stop everything now.” | Requests e-stop for every device touched by the session. |

You can use the same protocol without an agent:

```bash
mhp http://localhost:18921 describe summary
mhp http://localhost:18921 read block_temperature lid_closed
mhp http://localhost:18921 write target_temperature 95 --dry-run
mhp http://localhost:18921 invoke run_protocol \
  '{"steps":[{"temp":95,"hold_s":5}],"cycles":3}' --wait
mhp http://localhost:18921 estop "operator requested stop"
```

## How it works

An OpenMHP deployment has three parts:

1. **Device package** — a card, operating instructions, machine-readable descriptor,
   references, scripts, and a driver or adapter.
2. **Device server or lab node** — runs beside the instrument, translates OpenMHP calls into
   the native control API, publishes events, and enforces the device boundary.
3. **MCP bridge** — gives an agent a fixed set of OpenMHP tools regardless of whether the lab
   has two devices or two thousand.
4. **Gateway** (optional) — for labs whose network nothing outside may enter. Bench PCs dial
   out to it and register their instruments; agents reach them there. Nothing is opened inbound.

```text
agent harness
    │
    │ MCP: find, describe, read, write, invoke, job, run, data, lab, method, estop
    ▼
OpenMHP bridge ───── directory of compact device cards
    │
    │ MHP over stdio or HTTP/SSE
    ▼
device server / lab node
    │
    │ vendor SDK, serial, OPC UA, ROS 2, SiLA 2, MQTT, ...
    ▼
physical instrument
```

When the bench PC sits behind a lab firewall, the step between the bridge and the lab node
runs through the relay instead: the node dials out to a gateway over HTTPS and the bridge talks
to the gateway. See [Instruments behind the lab firewall](#instruments-behind-the-lab-firewall).

### Built to bridge the automation stack you already have

Labs have invested years in control systems such as **ROS 2, OPC UA, SiLA 2, MADSci,
PyLabRobot, and MQTT**. OpenMHP does not ask them to replace that work. It adds a common
agent-facing layer above it:

- OPC UA variables and methods become OpenMHP signals, settings, and actions.
- ROS 2 topics, services, and actions keep their native feedback and control paths.
- SiLA 2 properties and commands retain observable progress and cancellation.
- MADSci nodes expose their existing actions, status, and safety controls.
- PyLabRobot machines expose their existing operations through the same job model.
- MQTT topics, the way many labs already stream time-varying sensor data, become signals
  with a staleness window; command topics become settings and actions.

The adapter translates each technology into the same discovery, job, lease, telemetry, and
safety contract. The agent gets one way to interact with the lab while the lab keeps its
existing drivers, orchestration, and operational knowledge. See the
[adapter guide](https://openmhp.com/adapters) for the supported mappings.

Read the rationale in the [design principles](https://openmhp.com/design), see the components
in the [architecture guide](https://openmhp.com/architecture), and use [SPEC.md](SPEC.md) as the
normative protocol contract.

## Device packages

OpenMHP treats each device package the way Anthropic's
[Agent Skills](https://agentskills.io) treat procedural knowledge: the agent loads more detail
only as the task narrows. The package can hold everything the instrument owner wants an agent
to know without placing all of it in the model's context at once.

The package loads in three levels:

1. **Search the lab:** the agent sees only a compact device card: what the instrument is,
   where it is, and when to use it.
2. **Choose a device:** the agent loads that device's operating instructions: how to run it,
   what to watch, and what never to do.
3. **Prepare an action:** the agent requests only the exact signals, settings, actions,
   references, or tested scripts needed for the task.

![A device package loads progressively: a compact card during search, operating instructions after selection, and exact specifications or procedures on demand](assets/device-as-agent-skill.png)

This progressive disclosure keeps context small as the lab grows. In the included 2,000-device
scale demo, finding five candidates, opening one device, and loading the two items used takes
about 1,270 tokens, compared with about 1.22 million tokens for loading every descriptor up
front.

A package keeps human guidance and machine-enforced behavior together:

```text
devices/hotplate-01/
├── DEVICE.md          searchable card + operating instructions
├── descriptor.yaml    signals, settings, actions, limits, interlocks, safety
├── driver.py          native driver, BoundDriver, or adapter
├── sim.py             simulated twin (recommended)
├── references/        SOPs, manual excerpts, calibration notes
├── scripts/           tested end-to-end procedures
└── methods/           optional versioned methods for named procedures
```

`DEVICE.md` is readable by people and agents. `descriptor.yaml` contains the parts the runtime
can validate and enforce. The driver implements the hardware-specific hooks while the base
driver supplies the common protocol, job handling, notifications, and safety gates.

The model's context helps it reason; it is not the safety boundary. The driver remains beside
the hardware and checks limits, interlocks, approvals, leases, and device state on every call,
whether or not those rules are currently in the model's context.

Because the package is the rulebook, changing one is not the agent's to do either. The lab records
which package files were accepted for each device, refuses to operate a device whose files are not
those, and puts any change to a limit, interlock, or approval level to the owner with the exact diff
before it is enforced. `mhp lab accept <id>` is the owner's own way to accept one.

### Supported devices

[`supported-devices`](supported-devices) holds ready-made packages for instruments that talk to
OpenMHP directly: a driver, a simulated twin, operating instructions and a setup note each. Add
one to a lab with `mhp lab add github:kushalsinha/openmhp/supported-devices/<name>` (append
`--sim` for the twin), then set the limits to your own rig. The
[list](supported-devices/README.md) says, per device, whether the driver has been run on real
hardware or only against its twin, and carries a self-assessed score against the twelve
device-level criteria of Gottstein et al.'s autonomous-ready procurement profile (`mhp rubric
<folder>` shows the evidence). The full table with scores and setup routes is on
[openmhp.com/instruments](https://openmhp.com/instruments); in brief:

| Field | Packages | Instruments |
|---|---|---|
| Pharma, small molecule | 16 | HPLC/UPLC under Empower, OpenLab CDS and Chromeleon; EasyMax/OptiMax reactor; Karl Fischer titrator; 708-DS dissolution; Rotavapor R-300; Crystal16; Vapourtec R-Series; DSC/TGA under TRIOS; Bruker NMR (ICON-NMR); D8 PXRD; Cary UV-Vis/FTIR; LyoStar freeze dryer; Mettler Toledo and Sartorius balances |
| Pharma, biologics | 14 | Biostat bioreactor; ÄKTA avant; CLARIOstar/PHERAstar, SpectraMax and Spark plate readers; Hamilton STAR; Vi-CELL BLU; Octet BLI; Zetasizer DLS; Maurice CE; QuantStudio qPCR; Cytek Aurora cytometer; Innova shaker; Heracell CO2 incubator; Sigma centrifuge; BINDER stability chamber |
| Materials, synthesis and processing | 8 | Eurotherm and Nabertherm furnaces; MBRAUN glovebox; Quantos powder dosing; Laurell and Ossila spin coaters; Retsch planetary mill; AJA/Lesker sputter tools |
| Materials, characterization | 9 | Rigaku SmartLab and Panalytical Empyrean XRD; Phenom, TESCAN and ZEISS SEM; Instron under Bluehill; Anton Paar rheometer; Quantum Design PPMS; Dektak profilometer |
| Energy storage | 3 | Neware and Arbin battery cyclers; Gamry potentiostat (EIS) |
| Chemistry | 13 | IKA C-MAG and EUROSTAR; JULABO circulators; BioLogic SP-300 and PalmSens potentiostats; Ocean Insight and Wasatch/Blaze spectrometers; SRI 8610C GC; Orbitrap (IAPI); LC-MS worklists for MassLynx, SCIEX OS, MassHunter, Xcalibur; Elveflow OB1 and MUX; FloPro sampler |
| Biology | 7 | Opentrons Flex and OT-2; Micro-Manager microscopes; New Era and Tecan Cavro syringe pumps; Atlas Scientific EZO sensors; benchtop centrifuge (operator-run) |
| Physics | 6 | Keithley 2400 SMU; Lake Shore 33x/350; Pfeiffer TPG gauges; SRS SR830 lock-in; SRS RGA; Thorlabs PM100D |
| Engineering | 5 | Alicat flow controllers; LabJack T-series; NI-DAQmx; Rigol DP8xx supply; Rigol DS1000Z scope |

Three declarative drivers cover most bench
instruments with no package code at all: `serial_ascii` (text commands over USB or RS-232),
`scpi_visa` (SCPI over VISA, a raw socket or serial) and `modbus` (TCP or RTU registers); the
command map lives in `descriptor.yaml`. Every instrument that is not operator-run also answers
the reserved self-state signals (`calibration_status`, `qualification_status`, `usage_count`,
SPEC §4.6) and the runtime ones (`state`, `busy`, `connected`), so an agent asks every device
the same question about fitness for use.

A package carries the instrument's capabilities; the limits, interlocks and procedures are your
lab's. Keep your edited copies, your recipes and your SOPs in your lab's repository, review limit
changes like code, and deploy them to the bench computers that serve those devices. The packages
in [`openmhp/devices`](openmhp/devices) are simulated reference devices for learning and testing
the protocol.

## Connect a real instrument

Start with the route that matches the hardware:

| Instrument today | Recommended route |
|---|---|
| Already exposes OpenMHP | Scan and add its URL |
| Operated by a person | Use the manual driver so it can join procedures while preserving operator steps |
| Uses serial/USB text commands | Declare the commands in `descriptor.yaml`; no custom protocol code is needed |
| Already uses OPC UA, ROS 2, SiLA 2, MADSci, PyLabRobot, or MQTT | Use the matching adapter |
| Has a vendor Python SDK or another API | Subclass `Driver` or bind existing Python callables with `BoundDriver` |

From an agent, say:

```text
Onboard my IKA hotplate. I have the manual and can confirm its limits and stop procedure.
```

To serve packages from the bench computer attached to the instruments:

```bash
npx openmhp-cli node
```

Or use Python directly. The person at the bench knows which instrument they are standing next
to, so they name it; the package carries the vendor route and the node serves whatever packages
are in its folder:

```bash
pip install "openmhp[node]"       # the `node` extra adds serial, MQTT and mDNS, which a bench PC needs
mhp node add                      # lists the ready-made packages
mhp node add waters-empower-hplc  # fetches it, then asks the questions and leaves the node running
```

`add` downloads the package from this repository over HTTPS (no git on the lab PC), installs the
vendor client, and asks only what a person knows, with an example beside each question: the
Empower address, the user (its password goes to the OS keyring, never into a file), the project,
the node and system picked from a list the server gives. It writes `config.json`, proves the answers
against the instrument where the driver can (`Empower reachable, Arc_HPLC_1 idle`), asks for the
gateway pairing line if the lab has one, and either installs the background service or serves in
that window. Numbers and limits keep their defaults; the file is still plain JSON to edit.

```bash
mhp node setup waters-empower-hplc            # the same questions again (a port moved, a new address)
mhp node add ika-c-mag-hs7 --yes --set port=COM4 --no-pip   # scripted: no questions, defaults and --set
mhp node --check                              # what is still missing, in words; serves nothing
mhp node                                      # serves ~/.openmhp/devices; --install-service keeps it running
```

With no terminal (`--yes`, piped input) nothing is asked and what still needs an answer is said.
`--from <folder or .tar.gz>` takes a copied package instead of downloading, for a PC with no internet.
A package adds its questions in `config.schema.json` and can give its driver `discover` (choices
from the instrument) and `probe` (the one-line proof); without them the example's text fields are
asked, with `references/setup.md` as the help.

A node listens on `127.0.0.1` only, so by default no other machine can reach its ports; agents
beyond the lab reach it through the relay (`--join`), which opens nothing
inbound. To serve agents on the same network directly, pass `--host <this PC's LAN address>`: the
node then generates a token the first time it starts (`~/.openmhp/device_token`) and requires
`Authorization: Bearer <token>` on `/rpc` and `/events`. Copy it to the machine running the bridge
(`export OPENMHP_DEVICE_TOKEN=...`); discovery stays open, so `mhp lab scan` still finds the
devices. `--no-auth` serves the network without one, and callers from off the machine can then no
longer confirm approval-gated operations.

### An instrument PC that only has Python

A bench PC needs no Node, no agent and no second environment. Python 3.10 or newer and one
install are enough. The node pulls its package from this repository's `main`; `add` asks for the
gateway pairing line (from `mhp gateway pair` on the gateway) and offers to keep the node running:

```bash
pip install "openmhp[node]"
mhp node add waters-empower-hplc          # fetch, configure, pair with the gateway, install the service
mhp node --join https://gw.office ab12-cd34 --install-service   # or, for packages already in the folder
```

`npx openmhp-cli node` does the same through a prompt, for a PC that already has Node; it needs a
folder that already holds a package, so run `npx openmhp-cli mhp node add` first to see the
supported instruments and fetch one. Packages are downloaded when you add one, not shipped in the
wheel, so a package merged to `main` can be added before the next release, and
`pip install -U openmhp` is what refreshes the list `mhp node add` shows.

### Instruments behind the lab firewall

In most companies the instrument network is one nothing outside may enter, and IT will not open
a port for a lab PC. OpenMHP does not need one. The bench PC connects **outward** over HTTPS to
a gateway on the company network and registers its instruments; agents talk to the gateway. The
lab PC needs no AI agent and no network change, and working from home over the VPN is the same
as being at your desk.

![Bench PCs on the lab network dial out through the firewall to one gateway on the company network; agent machines in the office or on the VPN reach the same gateway with an agent token. Every arrow points at the gateway, none enters the lab.](assets/openmhp-gateway.svg)

```bash
# on the gateway machine, once
mhp gateway init
mhp gateway serve --install-service
mhp gateway pair                    # one-time code for one lab PC (15 minutes)
mhp gateway pair-agent              # one-time code for one agent machine (1 hour); send it in chat

# on the lab PC: `mhp node add <package>` asks for this line; or, for packages already there, once:
mhp node --join https://gw.office ab12-cd34

# on the agent machine, once; after that plain `mhp-mcp` reaches every instrument behind the gateway
mhp agent --join https://gw.office ef56-ab78
```

![One call through the relay: the lab PC holds a long-poll open on the gateway; the agent posts its request with its token; the gateway queues it under the agent's name and hands it to the open poll once; the driver runs it on the bench with every limit enforced; the reply comes back the same way. Offline means 503 at once, no answer means 504, and nothing is re-sent.](assets/openmhp-relay-flow.svg)

Every connection is outbound. A request is handed to the lab PC once or not at all: if the PC
is offline the agent gets a one-line error, never a silent retry. Agents hold agent tokens, the
lab PC's token never leaves it, and the gateway is the approval boundary. `mhp gateway check`
prints `OK` or `FIX` for the gateway, each lab PC and each instrument. The wire-level rules
are in `SPEC.md` (transports).

Before real operation, have the instrument owner review `DEVICE.md`, verify limits and
interlocks against the manual, prove out-of-range requests are refused, test e-stop and loss of
contact behavior, and keep the manufacturer's safety systems in place. OpenMHP is currently an
experimental preview tested primarily with simulators and fake vendor clients; supervise real
hardware deployments.

The full walkthrough is [Add an instrument](https://openmhp.com/add-a-device). For a lab with
many existing devices, see [Adapters](https://openmhp.com/adapters) and
[Lab nodes](https://openmhp.com/lab-nodes); for a closed instrument network, [Gateway and relay](https://openmhp.com/gateway).

## Contributing

OpenMHP is developed like a protocol project. Contributions should make the protocol clearer,
more interoperable, easier to implement, or better tested. A package for an instrument others
also own is welcome in [`supported-devices`](supported-devices); lab-specific limits, private
SOPs, and recipes belong in the lab's own repository rather than upstream.

Useful contributions include:

- proposals that resolve an open protocol or architecture question;
- work on items in the [published roadmap](https://openmhp.com/roadmap);
- improvements to the reference server, client, MCP bridge, discovery, jobs, events, leases,
  or safety behavior;
- adapter and interoperability improvements for ROS 2, OPC UA, SiLA 2, MADSci, PyLabRobot,
  MQTT, and other established automation systems;
- conformance tests that help independent OpenMHP implementations agree on behavior; and
- documentation, examples, and security reviews that make the protocol easier to implement
  correctly.

Before starting a substantial change, open an issue describing the protocol problem, the
affected implementations, and the behavior you propose. This gives the design discussion a
place to happen before code fixes one interpretation into the reference implementation.

### Set up a development checkout

```bash
git clone https://github.com/kushalsinha/openmhp.git
cd openmhp
python -m venv .venv
source .venv/bin/activate          # Windows: .venv\Scripts\activate
pip install -e ".[all]"
```

Run the test suite:

```bash
python tests/test_adapters.py
python tests/test_runs.py
python tests/test_safety_gates.py
python tests/test_inclusion.py
python tests/test_methods.py
```

### Contribution principles

- Start from a protocol or interoperability need, not a one-off lab customization.
- Keep the specification, reference implementation, and conformance tests aligned.
- Fail closed when hardware state or command outcome is uncertain.
- Preserve the fixed, device-independent tool surface.
- Add regression coverage for changes to safety, state, concurrency, or transport behavior.
- Document compatibility expectations for every adapter or wire-level change.

Read [CONTRIBUTING.md](CONTRIBUTING.md) for proposal and pull-request expectations. Protocol
questions, roadmap work, interoperability gaps, bugs, and design proposals belong in
[GitHub Issues](https://github.com/kushalsinha/openmhp/issues).

## Repository guide

| Path | Purpose |
|---|---|
| `openmhp/driver.py` | Driver base class, state machine, jobs, safety gates, and notifications |
| `openmhp/package.py` | Device-package loading and progressive description tiers |
| `openmhp/mcp_bridge.py` | Fixed MCP tool surface over a lab or directory |
| `openmhp/client.py` | Python client and multi-device `Lab` API |
| `openmhp/runs.py` | Plans, background runs, logs, and run artifacts |
| `openmhp/methods.py` | Versioned instrument methods and project history |
| `openmhp/adapters/` | OPC UA, ROS 2, SiLA 2, MADSci, PyLabRobot, MQTT, and callable bindings |
| `openmhp/drivers/` | Declarative drivers with no package code: `serial_ascii`, `scpi_visa`, `modbus`, and `manual` for operator-run instruments |
| `openmhp/rubric.py` | `mhp rubric`: scores a package against the device-level autonomous-ready procurement criteria |
| `scripts/build_registry.py` | Refreshes `openmhp/registry.json` and the supported-devices table (classes, twins, rubric scores) |
| `openmhp/devices/` | Bundled reference devices and simulated twins |
| `openmhp/recipes/` | Reusable multi-step procedures |
| `supported-devices/` | Ready-made device packages for specific instruments, each with a simulated twin |
| `openmhp/gateway.py` | `mhp gateway`: the relay agents reach when lab PCs sit behind a firewall |
| `openmhp/relay.py` | Node side of the relay: `mhp node --join` dials out and serves through the gateway |
| `openmhp/node_add.py` | `mhp node add <package>`: puts a ready-made device package on the instrument PC |
| `openmhp/node_setup.py` | `mhp node setup`: the questions (from `config.schema.json`), `config.json`, the driver's probe, gateway pairing, the service |
| `tests/` | Simulator and fake-client coverage, plus a relay end-to-end test |

## Project status

OpenMHP is a pre-1.0 experimental protocol. Expect breaking changes between minor versions.
The [roadmap](https://openmhp.com/roadmap) tracks what is implemented and what remains out of
scope. Use real hardware only with qualified supervision and independent safety controls.

## License

Apache License 2.0. See [LICENSE](LICENSE).

OpenMHP is an independent, community-driven project. It is not affiliated with, endorsed by,
or sponsored by Anthropic, the OPC Foundation, Open Robotics, the SiLA Consortium, MADSci,
PyLabRobot, or any instrument vendor. Names are used only to describe compatibility.