Metadata-Version: 2.1
Name: bayes_mef
Version: 0.1.8
Summary: Python implementation of the Bayesian MEF method
Home-page: https://github.com/microscopic-image-analysis/bayes-mef
License: BSD-3-Clause
Author: Shantanu Kodgirwar
Author-email: shantanu.kodgirwar@uni-jena.de
Requires-Python: >=3.9,<3.12
Classifier: License :: OSI Approved :: BSD License
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Requires-Dist: h5py (>=3.9.0,<4.0.0)
Requires-Dist: ipykernel (>=6.25.0,<7.0.0)
Requires-Dist: matplotlib (>=3.7.2,<4.0.0)
Requires-Dist: numpy (>=1.22,<=1.24.3)
Requires-Dist: scikit-image (>=0.21.0,<0.22.0)
Requires-Dist: scipy (>=1.11.1,<2.0.0)
Requires-Dist: tqdm (>=4.66.5,<5.0.0)
Project-URL: Repository, https://github.com/microscopic-image-analysis/bayes-mef
Description-Content-Type: text/markdown

# Bayesian MEF
[![PyPI](https://img.shields.io/pypi/v/bayes_mef)](https://pypi.org/project/bayes_mef/)
![Python 3.9+](https://img.shields.io/badge/python-3.9+-green.svg)
[![DOI](https://zenodo.org/badge/769216428.svg)](https://zenodo.org/doi/10.5281/zenodo.11103003)
[![License](https://img.shields.io/badge/License-BSD_3--Clause-purple.svg)](https://opensource.org/licenses/BSD-3-Clause)

Bayesian multi-exposure image fusion (MEF) is a general-purpose algorithm to achieve robust high dynamic range (HDR) imaging, particularly in scenarios with low signal-to-noise ratio (SNR) or variations in illumination intensity. This approach could especially be useful for high quality phase retrieval in coherent diffractive imaging (CDI). The algorithm, detailed in this publication ["Bayesian multi-exposure image fusion for robust high dynamic range ptychography"](https://doi.org/10.1364/OE.524284), explains the method and demonstrates the benefits for ptychography. To reproduce the results in the paper, see this [section](#reproducing-results). However, to get started, please install the package and check the demo usage below.

![demo_mef](https://github.com/microscopic-image-analysis/bayes-mef/assets/64919085/d00a8c5e-5e53-4b7e-856b-381cc99523ba)

To install this package from PyPI, 
```bash
pip install bayes_mef
```

## Usage

A minimal example demonstrating the usage of `BayesianMEF` by simulating some data.

[![Open In Colab](https://colab.research.google.com/assets/colab-badge.svg)](https://colab.research.google.com/github/microscopic-image-analysis/bayes-mef/blob/main/demo.ipynb)

```python
from bayes_mef import BayesianMEF
from skimage.data import camera
import numpy as np

# simulation params
truth = camera()
background = 60  # some background
times = np.array([0.1, 1, 10])  # exposure times or equivalently flux factors
threshold = 1500 # detector limit

# poisson data based on image formation model that is overexposed
data = [np.random.poisson(time * truth + background) for time in times]
data_saturated = np.clip(data, None, threshold, dtype="float")

# Bayesian MEF with optional field `update_fluxes`. Set it to `True` when
# flux factors (exposure times) are not accurately known.
mef_em = BayesianMEF(data_saturated, threshold, times, background, update_fluxes=False)
mef_em.run(n_iter=100)
fused_em = mef_em.fused_image.copy()
```

Additionally, one can also use the `ConventionalMEF` method as given in the paper.

```python
from bayes_mef import ConventionalMEF
mef_mle = ConventionalMEF(data_saturated, threshold, times, background)
mef_mle.mle()
fused_mle = mef_mle.fused_image.copy()
```
### Parallelized implementatation

In ptychography, one needs to fuse diffraction patterns for every scan position. Processing this for data over all scan positions can be slow for an iterative algorithm. Therefore, one can use the parallelized implementation for MEF `LaunchMEF`. Check the example below

```python
from bayes_mef import LaunchMEF

launch_mef = LaunchMEF(
    ptychogram_stack,    # ptychogram shape (n_exposures, n_scans, dp_x, dp_y)
    background,          # background shape (n_exposures, n_scans, dp_x, dp_y)
    flux_factors=None,   # if set to `None`, calculates automatically
    threshold=None,      # if set to `None`, calculates automatically
    update_fluxes=False, # set to `True` if you want to update fluxes
)

# runs Bayesian MEF in parallel by defining the number of CPUs `n_cpus`;
# returns the fused diffraction patterns with shape (n_scans, dp_x, dp_y) and updated flux factors
n_cpus = 20
n_iter = 150
fused_ptyem_stack, em_flux_factors = launch_mef.run_em(n_iter, n_cpus)
```

For a detailed usage, please check [synthetic_mef.py](scripts/synthetic_mef.py) that uses synthetic ptychography data.

## Reproducing results

To reproduce the ptychographic reconstruction results from the paper, please follow the below steps:

1. Please clone this repository and create a conda environment.
   ```bash
   git clone https://github.com/microscopic-image-analysis/bayes-mef.git
   cd bayes-mef
   conda create --name bayes-mef-venv python=3.11.5 
   ```
2. Now activate the environment and install the *pinned* dependencies.
   ```bash
   conda activate bayes-mef-venv
   pip install -r requirements.txt
   ```
3. Download the data from [Zenodo](https://zenodo.org/doi/10.5281/zenodo.10964222) with the following command:
   ```bash
   ./download_data.sh
   ```

4. Optional: For faster ptychographic reconstructions using GPU, please install `cupy` as given under its [installation guide](https://docs.cupy.dev/en/stable/install.html).

5. Run files from the [scripts/](scripts) directory for plotting the results.

## Citation
If you found this algorithm or the publication useful, please cite us at:
```tex
@article{Kodgirwar:24,
author = {Shantanu Kodgirwar and Lars Loetgering and Chang Liu and Aleena Joseph and Leona Licht and Daniel S. Penagos Molina and Wilhelm Eschen and Jan Rothhardt and Michael Habeck},
journal = {Opt. Express},
number = {16},
pages = {28090--28099},
publisher = {Optica Publishing Group},
title = {Bayesian multi-exposure image fusion for robust high dynamic range ptychography},
volume = {32},
month = {Jul},
year = {2024},
url = {https://opg.optica.org/oe/abstract.cfm?URI=oe-32-16-28090},
doi = {10.1364/OE.524284},
}
```



