Metadata-Version: 2.4
Name: apc-ups-security-auditor
Version: 0.1.9
Summary: Automated default-credential detection and password hardening for APC UPS NMC3 using Playwright.
Author: Bruno Teixeira
License: MIT
Project-URL: Homepage, https://github.com/hacktivism-github/netauto/tree/development/apc-nmc3-ui-scraper
Project-URL: Repository, https://github.com/hacktivism-github/netauto
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Requires-Python: >=3.9
Description-Content-Type: text/markdown
Requires-Dist: playwright>=1.47.0

# APC UPS Security Auditor (NMC3)

<p align="center">
  <a href="https://pypi.org/project/apc-ups-security-auditor/">
    <img src="https://img.shields.io/pypi/v/apc-ups-security-auditor.svg" alt="PyPI Version">
  </a>
  <a href="https://pypi.org/project/apc-ups-security-auditor/">
    <img src="https://img.shields.io/pypi/pyversions/apc-ups-security-auditor.svg" alt="Python Versions">
  </a>
  <a href="https://github.com/hacktivism-github/netauto/blob/development/LICENSE">
    <img src="https://img.shields.io/github/license/hacktivism-github/netauto.svg" alt="MIT License">
  </a>
</p>



Automated security auditing and UI-driven hardening for Schneider Electric APC UPS devices (NMC3) using [Playwright](https://playwright.dev/python/).

This tool automates browser interaction with the Schneider/APC NMC3 web interface to:

- Detect if default credentials (`apc`/`apc`) still work

- Automatically harden the default password

- Create a new Super User / Administrator account

- Failover to non-default login when needed

- Generate CSV/JSON reports

- Run in headless (fast) or headful (visual) modes

Developed for large-scale UPS deployments where vendors/suppliers often leave insecure defaults across multiple branch sites.

Published on PyPI for easy installation.

---

## Features
✔ Detect if default credentials still work

If the UPS still accepts `apc`/`apc`, the tool can automatically:

- change the password of the `apc` account

- create a new admin user

- record results in a report

✔ Harden the apc account password

Provide a strong new password once; the tool applies it to all hosts.

✔ Create new admin accounts

Custom username + password:

```--create-admin --new-admin-user <your admin username> --new-admin-pass "your hardened password"```

✔ Automatic mode (```--auto```)

Runs fully unattended, skipping all user prompts.

✔ Works headless or headful

- Headless (default) → fastest

- Headful → watch every step in a real browser

✔ CSV/JSON reporting

Ideal for audits, change-control logs, and compliance evidence.

✔ Check-only mode

Verify a single UPS without making any changes.

---

## Installation
__Option 1__ — Install from PyPI (preferred)
```
pip install apc-ups-security-auditor==1.0.9
```

This installs the CLI tool:
```
apc-ups-audit --help
```

__Option 2__ — Install from Source (development version)

If you want to run the latest development version directly from GitHub, you can install the package from the `apc-nmc3-ui-scraper` subdirectory of the repository.

#### 1. Clone the repository
```
git clone https://github.com/hacktivism-github/netauto.git
cd netauto/apc-nmc3-ui-scraper
```
#### 2. Create and activate a virtual environment (recommended)
```
python3 -m venv .venv
```
```
source .venv/bin/activate    # Linux/macOS
```
#### or
```
.\.venv\Scripts\activate      # Windows PowerShell
```
#### 3. Install the project in editable mode

```
python -m pip install --upgrade pip
pip install -e .
```
Install Playwright browsers:
```
playwright install
```
#### 4. Run the tool
See Usage below

__Option 3__ — Install directly from GitHub (bleeding-edge)

```
pip install "git+https://github.com/hacktivism-github/netauto@development#subdirectory=apc-nmc3-ui-scraper"
```
This will pull only the package from the subfolder, not the whole repo.

---

## Usage
- Prepare a list of UPS hosts (ups_hosts.txt):
```
10.x.x.x
172.16.x.x
192.168.x.x
...
```
__Note:__ use **`** (grave accent) to change the line (if using Windows PowerShell).

- Basic command (recommended)

Try default `apc`/`apc` → harden → create new admin → next host.
```
apc-ups-audit \
  --hosts ups_hosts.txt \
  --https \
  --create-admin \
  --new-admin-user <your admin user> \
  --auto \
  --report-csv results.csv
```

**This performs:**

1. Try login with `apc`/`apc`

2. If default credentials work →

   - harden `apc` password

   - create admin user

3. If default creds fail → automatically try fallback (`--current-user`, `--current-pass`)

4. Move to next host automatically

5. Save results to CSV

---

- Headful mode (watch the automation)
```
apc-ups-audit \
  --hosts ups_hosts.txt \
  --https \
  --create-admin \
  --new-admin-user <your admin user> \
  --auto \
  --headful
  ```

  ---

- Fully non-interactive (no prompts)
```
apc-ups-audit \
  --hosts ups_hosts.txt \
  --https \
  --auto \
  --create-admin \
  --new-admin-user <your admin user> \
  --new-admin-pass "your admin secure password" \
  --apc-new-pass "your apc hardened password" \
  --current-user <your current user> \
  --current-pass "your current password"
  ```

PowerShell:
```
apc-ups-audit.exe `
  --hosts ups_hosts.txt `
  --https `
  --headful `
  --apc-new-pass "Enter your hardened password" `
  --create-admin `
  --new-admin-user <Enter you desired admin user> `
  --new-admin-pass "Enter your hardened password" `
  --current-user <your current user> `
  --current-pass "your current password" `
  --auto `
  --report-csv report.csv

```

  ---

- Fallback login example

If `apc`/`apc` fails, try another known user:
```
apc-ups-audit \
  --hosts ups_hosts.txt \
  --https \
  --current-user <your current user> \
  --current-pass "your current password" \
  --create-admin \
  --new-admin-user <your admin user> \
  --auto
  ```

  ---
  
  - Check-only mode (no changes)

Verify a single UPS without modifying anything:

```
apc-ups-audit \
  --check-only <IP Address> \
  --https \
  --headful
```

__Output example:__
```
[RESULT] <IP Address>: default credentials NOT valid
```

This mode is ideal for:

- Spot checks
- Post-remediation validation
- Audit sampling

  ## Example Output (Headful + Auto)

```
(.venv) PS C:\Users\<user>\netauto\apc-nmc3-ui-scraper> apc-ups-audit.exe `
>>   --hosts ups_hosts.txt `
>>   --https `
>>   --headful `
>>   --apc-new-pass "Your hardened password" `
>>   --create-admin `
>>   --new-admin-user <your admin user> `
>>   --new-admin-pass "Your hardened password" `
>>   --auto `
>>   --report-csv report.csv
Loaded 2 host(s) from ups_hosts.txt
Using scheme: HTTPS
Browser will be HEADFUL (visible).


==============================================================
[*] Processing host: <IP Address>
==============================================================
    -> Opening https://<IP Address>/ ...
    -> Trying default credentials apc/apc …
    [*] Login page ready.
    [*] Set language to English.
    [*] Filled username and password.
    [*] Clicked Log On, waiting for home page...
    [✓] Login successful.
    [✓] Default login succeeded as apc. Hardening password and creating admin if requested…
    -> Hardening password for 'apc' on <IP Address>…
    [*] Navigating to User Management (click-only navigation)...
      -> Clicking 'Configuration'
      -> Clicking 'Security'
      -> Clicking 'Local Users'
      -> Clicking 'Management' (Local Users / userman.htm)
      -> Clicking user 'apc' under Super User Management
      -> Filling Current / New / Confirm Password fields...
      -> Clicking 'Next' (or fallback 'Apply')...
      -> Waiting for final confirmation page...
      -> Clicking FINAL 'Apply'
    [✓] Password change fully confirmed.
    [✓] Default user password hardened successfully.
    -> Creating new admin user 'your admin user' …
    [*] Navigating to Local Users to create admin user...
      -> Clicking 'Configuration'
      -> Clicking 'Security'
      -> Clicking 'Local Users'
      -> Opening 'Management' (user list)
      -> Clicking 'Add User'…
      -> Now on page: https://<IP Address>/NMC/uXfKb-aEKZloM5mXKqZlBg/usercfg.htm?user=
      -> Enabling new user (ticking 'Enable' checkbox)…
      -> Filling new admin user: your admin user
      -> Filling password fields…
      -> Setting user role (Super User / Administrator) if possible…
      -> Clicking 'Next'…
      -> On confirmation page, clicking 'Apply'…
    [✓] New admin user creation flow completed (Next + Apply).
    [✓] Admin user created successfully.
```
It automatically moves on to the next host as listed on the ups_hosts.txt file
```
[✓] CSV report written to report.csv

[*] All hosts processed.
```
If the default username/password are no longer accepted, it will attempt the fallback if provided (`--current-user`, `--current-pass`) otherwise it will skip to the next host or eventually exit. 

```
==============================================================
[*] Processing host: <IP Address>
==============================================================
    -> Opening https://<IP Address>/ ...
    -> Trying default credentials apc/apc …
    [*] Login page ready.
    [*] Set language to English.
    [*] Filled username and password.
    [*] Clicked Log On, waiting for home page...
    [-] Login did not reach home.htm – default credentials probably NOT valid.
    [-] Default login failed or undetermined. Trying fallback credentials (if configured)…
    [-] No fallback credentials provided; skipping host.

[✓] CSV report written to report.csv

[*] All hosts processed.
```
---  

  ## Command Line Options

 | __Flag__                          | __Purpose__                                                                   |
 | --------------------------------- | ----------------------------------------------------------------------------- |
 | -h, --help                        | show this help message and exit                                               |
 | `--version`                       | show program's version number and exit                                        |
 | `--hosts` HOSTS                   | Path to file containing UPS IPs/hostnames (one per line).                     |
 | `--check-only`                    | Verify a single host, no changes                                              |
 | `--https`                         | Use HTTPS instead of HTTP to open the web UI.                                 |
 | `--timeout` TIMEOUT               | Timeout (seconds) for page loads and login (default: 30).                     |
 | `--headful`                       | Run the browser in headful mode (visible window). Default is headless.        |
 | `--default-user` DEFAULT_USER     | Default username to test first (default: apc).                                |
 | `--default-pass` DEFAULT_PASS     | Default password to test first (default: apc).                                |
 | `--apc-new-pass` APC_NEW_PASS     | New hardened password to set for the default user (e.g. 'apc') when default   |
 |                                   | credentials are still valid. If omitted and not in --auto, you will be        |
 |                                   | prompted once.                                                                |
 | `--current-user` CURRENT_USER     | Fallback username to use when default login fails (default: apc).             |
 | `--current-pass` CURRENT_PASS     | Fallback password to use when default login fails. If omitted and             |
 |                                   | current-user != default-user, you may be prompted (except when using --auto). |
 | `--create-admin`                  | Create a new Super User admin account on hosts where login succeeds.          |
 | `--new-admin-user` NEW_ADMIN_USER | New admin username to create (used with --create-admin).                      |
 | `--new-admin-pass` NEW_ADMIN_PASS | New admin password to set (used with --create-admin). If omitted and not in   |
 |                                   | --auto, you will be prompted.                                                 |
 | `--auto`                          | Run without interactive prompts for admin creation (non-interactive mode).    |
 | `--report-csv` REPORT_CSV         | Path to CSV report file to write scan results (optional).                     |
 | `--report-json` REPORT_JSON       | Path to JSON report file to write scan results (optional).                    |

---

## Supported Devices

This tool is designed for:

- Schneider Electric **APC UPS Network Management Card 3 (NMC3)**
- Web UI using pages like:
  - `logon.htm`
  - `home.htm`
  - `userman.htm`
  - `usercfg.htm`
  - `usrcnfrm.htm`

Devices tested include:

- APC Easy UPS 3S
- APC Smart-UPS with NMC3 firmware 2022–2025

---

## Requirements

- Python 3.9 or later
- Playwright

Install dependencies:

```
pip install playwright
playwright install
```

---

 ## Demo

```
I'll be adding the demo soon!
```
---

## Disclaimer

This tool modifies administrator credentials on APC UPS devices.
Use responsibly and ensure:
   - You have explicit authorization
   - You follow organizational security policies
   - New passwords are stored securely
   - Changes are properly documented

The author is not responsible for misuse or misconfiguration.

---

## License

This project is licensed under the **MIT License**.  
See [`LICENSE`](https://github.com/hacktivism-github/netauto/blob/development/LICENSE) for details.

---

## Contributions

Pull requests, issues, and feature requests are welcome!

---

## Author

Bruno Teixeira
Network & Security Automation — Angola