Metadata-Version: 2.4
Name: dertwin
Version: 0.2.0
Summary: Digital twin simulator for distributed energy resources — BESS, PV inverters, energy meters
Author-email: Oleksandr Spivak <oleksdertwin@gmail.com>
License: MIT License
        
        Copyright (c) 2026 Oleksandr Spivak
        
        Permission is hereby granted, free of charge, to any person obtaining a copy
        of this software and associated documentation files (the "Software"), to deal
        in the Software without restriction, including without limitation the rights
        to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
        copies of the Software, and to permit persons to whom the Software is
        furnished to do so, subject to the following conditions:
        
        The above copyright notice and this permission notice shall be included in all
        copies or substantial portions of the Software.
        
        THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
        IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
        FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
        AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
        LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
        OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
        SOFTWARE.
        
Project-URL: Homepage, https://github.com/AlexSpivak/dertwin
Project-URL: Repository, https://github.com/AlexSpivak/dertwin
Project-URL: Bug Tracker, https://github.com/AlexSpivak/dertwin/issues
Keywords: modbus,digital-twin,bess,energy,ems,der,simulator
Classifier: Development Status :: 3 - Alpha
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: Science/Research
Classifier: License :: OSI Approved :: MIT License
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Topic :: Scientific/Engineering
Classifier: Topic :: Software Development :: Testing
Requires-Python: >=3.11
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: pymodbus<3.13,>=3.8
Requires-Dist: PyYAML>=6.0
Provides-Extra: dev
Requires-Dist: pytest>=7.0; extra == "dev"
Requires-Dist: pytest-asyncio>=0.21; extra == "dev"
Provides-Extra: pvlib
Requires-Dist: pvlib>=0.11; extra == "pvlib"
Dynamic: license-file

# DER Twin

Digital Twin infrastructure for modern energy systems.

**DER Twin** is a lightweight simulator for Distributed Energy Resources (DER) — BESS, PV inverters, CHP units, energy meters, and grid models — exposed via Modbus TCP and Modbus RTU. Use it for EMS development, protocol testing, integration validation, and control algorithm sandboxing without touching real hardware.

---

## ⚡ Quickstart

### Option A — pip install

```bash
pip install dertwin
```

Bring your own site config and register maps:

```bash
dertwin -c path/to/your/config.json
```

You should see:
```
INFO | Building site: my-site
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Simulation engine started | step=0.100s
```

The simulator is now accepting Modbus TCP connections on the ports defined in your config.

### Option B — Run from source

```bash
git clone https://github.com/AlexSpivak/dertwin.git
cd dertwin
python -m venv .venv && source .venv/bin/activate
pip install -e .
python -m dertwin.main -c configs/simple_config.json
```

### Option C — Run with Docker

```bash
git clone https://github.com/AlexSpivak/dertwin.git
cd dertwin
python generate_compose.py configs/simple_config.json
docker compose up --build
```

`generate_compose.py` reads the config and generates a `docker-compose.yml` with the correct ports automatically. No manual port configuration needed. For mixed-protocol configs with RTU, see [Docker with RTU](#docker-with-rtu) below.

---

## 🔌 Connect an EMS

With the simulator running, start the example EMS from a second terminal:

```bash
cd examples
python main_simple.py
```

You'll see the EMS connecting over Modbus and cycling the BESS between 40–60% SOC:

```
[EMS] Connected to BESS
[EMS] Starting in CHARGE mode
[EMS] STATUS=1 | SOC= 42.30% | P=  -20.00 kW | MODE=charge
[EMS] STATUS=1 | SOC= 44.10% | P=  -20.00 kW | MODE=charge
...
[EMS] Reached 60% → switching to DISCHARGE
```

For a full multi-device site (dual BESS + PV + CHP + energy meter + external models):

```bash
python -m dertwin.main -c configs/full_site_config.json
# in another terminal:
python examples/main_full.py
```

You'll see the CHP go through its realistic startup sequence (~2 minutes) before reaching `RUNNING` and dispatching power, while the BESS units cycle and the energy meter aggregates the full site balance.

For a mixed-protocol site (BESS on TCP + PV and meter on RTU), see [Mixed Protocol Example](#-mixed-protocol-example-tcp--rtu) below.

---

## 🔁 Dynamic Asset Membership

In addition to config-driven site definitions, DERTwin's `SiteController` supports adding and removing assets at runtime. Use this for scenario scripts ("at t=300s, a new PV inverter comes online"), live demos, and EMS-driven sites where the asset roster is decided by an external controller.

```python
from dertwin.controllers.site_controller import SiteController
import asyncio

# Build an empty site
site = SiteController({
    "site_name": "demo",
    "step": 0.1,
    "real_time": True,
    "register_map_root": "configs/register_maps",
    "assets": [],
})
site.build()
asyncio.create_task(site.start())

# Add an asset live — protocol server starts immediately, site power model picks it up next tick
await site.add_asset({
    "asset_id": "bess-01",
    "type": "bess",
    "ip": "127.0.0.1",
    "port": 55001,
    "unit_id": 1,
    "capacity_kwh": 200.0,
    "initial_soc": 50.0,
})

# ...later, remove it
await site.remove_asset("bess-01")
```

Key properties:
- The site power model captures device lists by reference, so dynamically added generators show up in the energy meter's grid balance on the next tick — no rebuild required.
- `add_asset` is idempotent: re-registering an existing `asset_id` is a no-op.
- `remove_asset` cancels the protocol task and shuts down the server cleanly; the engine keeps running for the remaining assets.
- See [`dertwin/controllers/README.md`](dertwin/controllers/README.md) for the full API and the two supported configuration shapes (legacy `protocols: [...]` for multi-protocol use, flat spec for single-TCP-endpoint runtime use).

---

## 🧱 Features

- Async Modbus TCP and RTU servers built on `pymodbus`
- Mixed-protocol support — TCP and RTU devices on the same site
- Full 16-bit Modbus address space on all four datastores (discrete inputs, coils, input registers, holding registers)
- Per-register function code routing — FC02 discrete inputs for binary flags, FC03/04 for analog telemetry
- Per-register endianness — big-endian default, little-endian for Sungrow/Carlo Gavazzi-style devices
- Realistic CHP simulation — MWM TEM Evolution-compatible state machine, configurable startup timings, thermal physics, heat output
- Config-driven site topology — add devices by editing JSON
- Runtime asset management — `add_asset` / `remove_asset` for live scenario scripting and EMS-driven rosters
- Hard SOC limits on BESS assets — SOC lands exactly on the limit, then power reads zero while the setpoint stays as written
- Optional SOC persistence across restarts
- Location- and date-aware clear-sky irradiance — correct sunrise, sunset and seasonal peak for any latitude and day of the year
- Stochastic cloud cover with persistent day-to-day weather regimes, seedable and reproducible
- Plane-of-array irradiance for tilted, oriented PV arrays, with DC/AC ratio and inverter clipping
- Irradiance from a CSV, for replaying measured data
- Stochastic site load — daily profile, weekday/weekend factor, slow mean-reverting drift and fast noise, all seedable
- Ambient temperature, grid frequency, and grid voltage models
- Multi-device support across independent ports
- External model events (voltage sags, frequency deviations)
- Simulation start time control (`start_time_h`) — start at noon, peak load, etc.
- Docker support with auto-generated Compose files and RTU-over-TCP bridging
- Deterministic simulation with seeded random models
- Fully tested with `pytest`

---

## 📦 Repo Structure

```
dertwin/
├── configs/
│   ├── register_maps/              # Modbus register definitions (YAML)
│   ├── simple_config.json          # Single BESS — good starting point
│   ├── demo_config.json            # BESS + PV + meter
│   ├── full_site_config.json       # BESS + BESS + PV + CHP + meter + external models
│   ├── mixed_protocol_config.json  # BESS (TCP) + PV (RTU) + meter (RTU)
│   ├── stockholm_site_config.json  # Northern Europe, 59.33 N — clear-sky PV, clouds, stochastic load
│   └── kyiv_site_config.json       # Ukraine, 50.45 N — same code, different place
├── dertwin/
│   ├── core/                # Clock, engine, register map loader
│   ├── controllers/         # Site and device orchestration (incl. dynamic add/remove)
│   ├── devices/             # BESS, PV, CHP, energy meter, external models
│   ├── protocol/            # Modbus TCP + RTU servers
│   ├── telemetry/           # Telemetry dataclasses
│   └── main.py
├── examples/
│   ├── simple/              # Single BESS EMS example
│   ├── full/                # Multi-device EMS example with CHP (TCP)
│   ├── mixed/               # Mixed-protocol EMS example (TCP + RTU)
│   ├── seasonal/            # Print a simulated day from a location-aware config
│   └── protocol/            # Shared Modbus TCP and RTU clients
├── state/                   # BESS SOC state files (gitignored)
├── tests/                   # Full test suite
├── generate_compose.py      # Docker Compose generator
├── docker-entrypoint.sh     # Container entrypoint (socat + RTU bridge)
└── Dockerfile
```

---

## ⚙️ Configuration

Sites are defined in JSON. Each asset declares its type, parameters, and protocol bindings:

```json
{
  "site_name": "my-site",
  "step": 0.1,
  "real_time": true,
  "start_time_h": 12.0,
  "register_map_root": "register_maps",
  "external_models": {
    "irradiance": { "peak": 1000.0, "sunrise": 6.0, "sunset": 18.0 },
    "grid_frequency": { "nominal_hz": 50.0, "noise_std": 0.002, "seed": 42 }
  },
  "assets": [
    {
      "type": "bess",
      "capacity_kwh": 100.0,
      "initial_soc": 60.0,
      "protocols": [{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55001, "unit_id": 1, "register_map": "bess_modbus.yaml" }]
    },
    {
      "type": "chp",
      "rated_kw": 4000.0,
      "heat_to_power_ratio": 1.0,
      "min_load_percent": 30.0,
      "max_load_percent": 110.0,
      "protocols": [{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55002, "unit_id": 1, "register_map": "chp_modbus.yaml" }]
    }
  ]
}
```

**`real_time: true`** — engine runs its own loop, use for `dertwin` CLI and EMS examples
**`real_time: false`** — caller drives the clock via `step_once()`, use for tests
**`sim_start_utc`** — absolute UTC instant the simulation starts from, ISO 8601 (e.g. `"2025-10-31T00:00:00Z"`). Internal time is always UTC. Required by the clear-sky irradiance model, which has no sun position without a date. Omit it and the clock sits at the Unix epoch, so `start_time_h` keeps its original meaning.
**`start_time_h`** — offsets the clock on startup (e.g. `12.0` for noon), relative to `sim_start_utc`'s date. All external models start from this time.
**`data_root`** — path for CSV inputs (`irradiance.series_csv`), resolved relative to the config file. Defaults to the working directory.
**`register_map_root`** — path to register map directory, resolved relative to the working directory where you run `dertwin`
**`state_root`** — path for device state files (`state_file` on a BESS asset), resolved relative to the config file. Defaults to the working directory.
**`data_root`** — path for CSV inputs (`load.profile.csv`, irradiance series), resolved relative to the config file. Defaults to the working directory.
**`ip: "0.0.0.0"`** — required when running inside Docker so port mapping works. Use `127.0.0.1` for local-only.

Unknown asset keys are rejected at build time with a "did you mean" hint, so a typo fails loudly instead of being silently ignored.

### Supported asset types

| `type` | Class | Notable parameters |
|---|---|---|
| `bess` | `BESSSimulator` | `capacity_kwh`, `initial_soc`, `max_charge_kw`, `max_discharge_kw`, `ramp_rate_kw_per_s`, `soc_min_percent`, `soc_max_percent`, `limit_mode`, `round_trip_eff`, `charge_efficiency`, `discharge_efficiency`, `self_discharge_percent_per_day`, `state_file` |
| `inverter` | `PVSimulator` | `rated_kw` / `ac_rating_kw`, `dc_capacity_kw`, `dc_ac_ratio`, `tilt_deg`, `azimuth_deg`, `albedo`, `derate` / `losses`, `module_efficiency`, `area_m2`, `temp_coefficient`, `noct_c` |
| `chp` | `CHPSimulator` | `rated_kw`, `heat_to_power_ratio`, `min_load_percent`, `max_load_percent` |
| `energy_meter` | `EnergyMeterSimulator` | (no parameters — observes the site power model) |

### Location-aware example sites

Two complete sites, config-only — nothing in `dertwin/` knows about either
place, and a test guards that:

| Config | Place | Plant |
|---|---|---|
| [`configs/stockholm_site_config.json`](configs/stockholm_site_config.json) | Stockholm, 59.33 N | 40 kW DC / 30 kW AC at 45°, 120 kWh BESS |
| [`configs/kyiv_site_config.json`](configs/kyiv_site_config.json) | Kyiv, 50.45 N | 36 kW DC / 30 kW AC at 35°, 100 kWh BESS |

Print a simulated day from either, with no dependencies beyond the standard
library:

```bash
python examples/seasonal/plot_day.py stockholm --clear
```

```
    UTC   elev     GHI     POA      PV    load     grid    SOC
           deg    W/m2    W/m2      kW      kW       kW      %
  ------------------------------------------------------------
  08:00   10.7   163.4   435.3   16.01   51.57    35.66   55.0
  10:00   16.6   269.1   666.3   23.62   52.57    28.97   55.0
  12:00   14.6   233.6   590.1   21.00   55.84    34.78   54.9
  14:00    5.6    81.8   213.7    7.95   47.51    39.40   54.9

  GHI              ▁▂▄▅▆▇▇████▇▇▆▅▄▂▁                    peak 274.1
```

Clear-sky resource on the same three dates — this is what the geography buys:

| | Stockholm | Kyiv |
|---|---|---|
| Daylight, 31 Oct | 8.72 h | 9.68 h |
| Daylight, 21 Jun | 18.28 h | 16.23 h |
| Daylight, 21 Dec | 5.73 h | 7.78 h |
| GHI peak, 31 Oct | 274 W/m² | 411 W/m² |
| GHI peak, 21 Jun | 839 W/m² | 905 W/m² |
| GHI peak, 21 Dec | 108 W/m² | 239 W/m² |

See [`examples/seasonal/README.md`](examples/seasonal/README.md) for what the
two *plants* then do with that resource, which is a different question.

### BESS SOC limits, efficiency and persistence

The SOC window is defended with a **hard stop**: in the step that would cross a
limit, power is clamped so SOC lands exactly on it, and from then on reported
active power is exactly `0` while the setpoint keeps pushing that way. The
setpoint register keeps whatever the EMS wrote, so dispatch resumes by itself
once the pack has headroom — and the energy counters, the site power balance
and the meter all follow the actual (clamped) power, not the setpoint.

```json
{
  "type": "bess",
  "capacity_kwh": 100.0,
  "initial_soc": 60.0,
  "soc_min_percent": 10.0,
  "soc_max_percent": 95.0,
  "limit_mode": "hard",
  "max_charge_kw": 50.0,
  "max_discharge_kw": 50.0,
  "round_trip_eff": 0.92,
  "self_discharge_percent_per_day": 0.0,
  "state_file": "state/bess-1.json",
  "state_save_interval_s": 60.0
}
```

**`soc_min_percent` / `soc_max_percent`** — the hard window. Omit them and it
follows `soc_limits.lower_2` / `soc_limits.upper_2`, which is also what the
Modbus `soc_lower_limit_2` / `soc_upper_limit_2` commands write, so an EMS can
move the hard limits at runtime.
**`limit_mode`** — `"hard"` (default) or `"taper"` for the pre-0.2 linear
derating ramp between the `_1` and `_2` thresholds.
**`round_trip_eff`** — split as `sqrt()` across charge and discharge.
`charge_efficiency` / `discharge_efficiency` override it per direction.
**`state_file`** — opt-in SOC persistence. Omit it and every start is a cold
start at `initial_soc`. When set, SOC and the lifetime counters are written
atomically on an interval and on shutdown, and restored on the next start; the
first boot, a missing file or an unusable one falls back to `initial_soc` and
logs why.

### Solar irradiance

Three models, selected by `external_models.irradiance.model`:

| `model` | Behaviour |
|---|---|
| `sinusoidal` | The original fixed-shape day: a sine between a configured sunrise and sunset, identical every day of the year everywhere on earth. **The default**, so existing configs are untouched. |
| `clearsky` | Real solar geometry for the date and location, times a stochastic cloud index. Selected automatically as soon as you give a `latitude`. |
| `series` | GHI replayed from a CSV. |

```json
{
  "sim_start_utc": "2025-10-31T00:00:00Z",
  "external_models": {
    "irradiance": {
      "latitude": 59.3293,
      "longitude": 18.0686,
      "timezone": "Europe/Stockholm",
      "altitude_m": 44.0,
      "clearsky_model": "ineichen",
      "linke_turbidity": 3.0,
      "cloud": {
        "enabled": true,
        "model": "ar1",
        "mean_kt": 0.48,
        "phi": 0.65,
        "sigma_day": 0.9,
        "kt_min": 0.08,
        "intraday_sigma": 0.07,
        "intraday_tau_s": 900.0,
        "seed": 59
      }
    }
  },
  "assets": [
    {
      "type": "inverter",
      "ac_rating_kw": 30.0,
      "dc_capacity_kw": 36.0,
      "tilt_deg": 45.0,
      "azimuth_deg": 180.0,
      "derate": 0.86
    }
  ]
}
```

**`latitude` / `longitude`** — degrees, longitude positive east. Giving a
latitude is what switches the model on.
**`timezone`** — label only, for logs and examples. Internal time is always UTC.
**`clearsky_model`** — `ineichen` (default, adds altitude and turbidity),
`haurwitz` (elevation only), or `pvlib` (needs `pip install "dertwin[pvlib]"`).
**`linke_turbidity`** — ~2 very clear, ~3 clear continental, ~5–6 hazy summer.
**`cloud`** — day-to-day weather regimes as an AR(1) process plus intraday
Ornstein-Uhlenbeck variability. `phi` sets how long overcast spells last,
`mean_kt` the long-run clear-sky fraction. On by default once a location is
given; set `seed` for a reproducible run or `enabled: false` for a cloudless
sky.
**`series_csv`** — replay recorded data. With `series_column: "kt"` it drives
the cloud index and keeps the clear-sky curve; otherwise it is absolute GHI in
W/m².

What this buys, at Stockholm (59.33 N):

| Date | Daylight | Clear-sky GHI peak |
|---|---|---|
| 21 Jun | 18.3 h | ~819 W/m² |
| 31 Oct | 8.7 h | ~256 W/m² |
| 21 Dec | 5.7 h | ~93 W/m² |

The `sinusoidal` model gives all three 12.0 h and 1000 W/m².

### PV array orientation

`tilt_deg` and `azimuth_deg` (clockwise from true north; 180 is due south)
enable plane-of-array transposition. Without a tilt, irradiance is taken as
already in-plane — the pre-0.2 behaviour. `dc_capacity_kw` (or `dc_ac_ratio`)
oversizes the array relative to `ac_rating_kw` so the inverter actually clips,
as real plants do; leave both out and DC/AC stays 1.0 and nothing ever clips.
See [`dertwin/devices/pv/README.md`](dertwin/devices/pv/README.md).
### Site load

The site load is multiplicative, so each piece can be configured without
fighting the others:

```
load_kw = base_kw × profile(hour) × weekday × drift × (1 + noise)
```

```json
{
  "external_models": {
    "load": {
      "base_kw": 50.0,
      "profile": {
        "model": "hourly",
        "hourly": [0.55, 0.52, 0.50, 0.50, 0.52, 0.60, 0.75, 0.95,
                   1.05, 1.05, 1.00, 0.98, 0.95, 0.95, 0.98, 1.05,
                   1.20, 1.35, 1.30, 1.15, 1.00, 0.85, 0.70, 0.60],
        "interpolate": true,
        "normalize": true
      },
      "weekday_factor": 1.0,
      "weekend_factor": 0.75,
      "start_weekday": "monday",
      "drift": { "sigma": 0.12, "tau_s": 10800.0, "min_factor": 0.7, "max_factor": 1.3 },
      "noise": { "sigma": 0.02, "tau_s": 30.0 },
      "min_kw": 0.0,
      "max_kw": null,
      "seed": 7
    }
  }
}
```

**`base_kw`** — the *average* load. The profile is normalised to a daily mean of
1.0, so changing the shape never moves the average.
**`profile.model`** — `flat` (default, the pre-0.2 constant), `hourly` (24
factors), `parametric` (a night baseline with morning and evening bumps), or
`csv` (an hour-of-day table at any resolution; a `kw` column sets `base_kw`
from its mean).
Hourly factors sit at their **hour centres** and interpolate circularly, so
there is no discontinuity at midnight.
**`weekend_factor`** — applied on Saturday and Sunday. The clock is an offset
from the start of the run rather than a date, so `start_weekday` places the week
and it advances at each simulated midnight.
**`drift`** — slow mean-reverting random walk, the "this week is busier than
usual" term. `sigma` is the standard deviation of the multiplicative factor and
`tau_s` its correlation time; bounded by `min_factor` / `max_factor`.
**`noise`** — the same process on a timescale of seconds.
**`seed`** — one seed drives both random terms. Drift and noise are off unless
configured.

The legacy `external_models.power.base_load_w` still works and is still a flat
load; a `load` block supersedes it, and a `load` block with no `base_kw`
inherits its value.
### Migrating from 0.1.x

Every existing config key still works and no config in `configs/` needed
editing. Irradiance in particular is unchanged until you ask for more: the
`sinusoidal` model stays the default, and the date- and location-aware one
switches on only once you give a `latitude`.

Two BESS behaviours did change:

- **SOC limits no longer taper.** `soc_limits.lower_2` / `upper_2` are now hard
  stops that SOC lands on exactly; `lower_1` / `upper_1` are accepted and
  ignored. Set `"limit_mode": "taper"` per asset to keep the old ramp.
- **`round_trip_eff` now has an effect.** The pre-0.2 model multiplied by the
  efficiency on both the charge and discharge leg, so the realised round-trip
  efficiency was always 1.0 no matter what was configured. Charging now stores
  less than arrives at AC and discharging drains more than reaches AC, so a
  cycle costs what the config says it costs.

Also fixed: `service_current` now reports amps (it reported kW into an amps
register), and reactive/apparent power are derived from the clamped power
instead of the pre-clamp setpoint.

### Protocol Configuration

Each asset's `protocols` array supports both Modbus TCP and Modbus RTU. A single device can expose multiple protocols simultaneously.

**Modbus TCP:**
```json
{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55001, "unit_id": 1, "register_map": "bess_modbus.yaml" }
```

**Modbus RTU:**
```json
{ "kind": "modbus_rtu", "port": "/tmp/dertwin_device", "baudrate": 9600, "parity": "N", "stopbits": 1, "unit_id": 1, "register_map": "bess_modbus.yaml" }
```

RTU parameters `baudrate`, `parity`, `stopbits`, `bytesize`, and `timeout` all have sensible defaults (9600/N/1/8/1.0) and can be omitted.

**Register map fields:**

| Field | Required | Description |
|---|---|---|
| `name` | yes | Human-readable label, used in logs and the EMS client |
| `internal_name` | yes | Maps to the device's internal telemetry or command field — must match the attribute name in the corresponding telemetry class (see [`dertwin/telemetry/README.md`](dertwin/telemetry/README.md)) |
| `address` | yes | Modbus register address (0–65535) |
| `type` | yes | `uint16`, `int16`, `uint32`, `int32` |
| `scale` | yes | Multiplier applied on read, divisor applied on write |
| `count` | yes | Number of registers (1 for 16-bit, 2 for 32-bit) |
| `func` | yes | Function code: `0x02` discrete input read, `0x03` holding read, `0x04` input read, `0x06` single write, `0x10` multi-register write |
| `direction` | yes | `read` or `write` |
| `endian` | no | `big` (default) or `little` — for devices like Sungrow BESS and Carlo Gavazzi meters that use little-endian 32-bit register layout |
| `unit` | no | Physical unit label (V, kW, Hz, etc.) |
| `description` | no | Free-text note |
| `options` | no | Enum mapping for status/mode registers |

`name` and `internal_name` can differ — `name` is what the EMS client sees, `internal_name` is what the device simulator uses internally. For example, `on_grid_power_setpoint` (name) maps to `active_power_setpoint` (internal_name) on the BESS device.

For detailed architecture and per-package docs, see [`dertwin/README.md`](dertwin/README.md).

---

## 🔀 Mixed Protocol Example (TCP + RTU)

This example runs a site with BESS on Modbus TCP and PV + energy meter on Modbus RTU. The EMS controls the BESS over TCP and monitors the RTU devices for observability.

### Prerequisites

Install `socat` to create virtual serial port pairs:

```bash
# macOS
brew install socat

# Ubuntu / Debian
sudo apt install socat
```

### Running the example

**Terminal 1** — create virtual serial pairs and start the simulator:

```bash
# Create virtual serial port pairs (simulator <-> EMS client)
socat -d -d pty,raw,echo=0,link=/tmp/dertwin_pv pty,raw,echo=0,link=/tmp/dertwin_pv_client &
socat -d -d pty,raw,echo=0,link=/tmp/dertwin_meter pty,raw,echo=0,link=/tmp/dertwin_meter_client &

# Start the simulator (from repo root)
dertwin -c configs/mixed_protocol_config.json
```

You should see:
```
INFO | Building site: mixed-protocol-site
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_pv | baudrate=9600 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_meter | baudrate=9600 | unit=1
INFO | Simulation engine started | step=0.100s
```

**Terminal 2** — run the mixed-protocol EMS:

```bash
cd examples
python main_mixed.py
```

Expected output:
```
[BESS-1] TCP connected
[PV] RTU connected
[METER] RTU connected
[BESS-1] Starting in CHARGE mode

[EMS] Mixed-protocol EMS running
  [BESS-1] RUN  | SOC= 50.0% | P= -30.00 kW | MODE=charge
  [PV]    P= 16.40 kW (producing)
  [METER] Grid= +23.57 kW (importing) | Freq=50.000 Hz | Import=0.1 kWh | Export=0.0 kWh
```

The key point: socat creates a **pair** of linked pseudo-terminals for each connection. The simulator opens one end (`/tmp/dertwin_pv`) and the EMS client opens the other (`/tmp/dertwin_pv_client`). Both sides must use different ends of the pair.

If RTU serial ports are unavailable, the EMS will still run with BESS-only control — PV and meter telemetry will show as unavailable.

---

## 🐳 Docker

### TCP-only configs

For configs that only use Modbus TCP, Docker setup is straightforward:

```bash
python generate_compose.py configs/full_site_config.json
docker compose up --build
```

TCP ports are mapped automatically from the config. Connect your EMS to `localhost:<port>`.

### Docker with RTU

RTU serial devices use pseudo-terminals (`/dev/pts/`) which exist only inside the container's kernel namespace and can't be accessed from the host via volume mounts. The entrypoint solves this by bridging each RTU serial port to a TCP port inside the container using a Python asyncio relay. From the host, `socat` converts the TCP connection back into a local PTY that the EMS opens as a normal serial port.

**Step 1** — generate the compose file and start the container:

```bash
python generate_compose.py configs/mixed_protocol_config.json
docker compose up --build
```

You should see:
```
[entrypoint] Creating serial pair: /tmp/dertwin_pv <-> /tmp/dertwin_pv_bridge
[entrypoint] Bridging /tmp/dertwin_pv_bridge -> TCP port 56001
[bridge] /tmp/dertwin_pv_bridge <-> TCP :56001
[entrypoint] Creating serial pair: /tmp/dertwin_meter <-> /tmp/dertwin_meter_bridge
[entrypoint] Bridging /tmp/dertwin_meter_bridge -> TCP port 56002
[bridge] /tmp/dertwin_meter_bridge <-> TCP :56002
[entrypoint] RTU bridges ready
[entrypoint] Starting DERTwin simulator
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_pv | baudrate=9600 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_meter | baudrate=9600 | unit=1
```

`generate_compose.py` detects RTU ports in the config and automatically exposes the bridge TCP ports (56001, 56002, ...) alongside the regular Modbus TCP ports in the generated `docker-compose.yml`.

**Step 2** — in a separate terminal on the host, create local PTY endpoints (requires `socat`):

```bash
socat pty,raw,echo=0,link=/tmp/dertwin_pv_client tcp:localhost:56001 &
socat pty,raw,echo=0,link=/tmp/dertwin_meter_client tcp:localhost:56002 &
```

This creates `/tmp/dertwin_pv_client` and `/tmp/dertwin_meter_client` on the host — the same paths the EMS expects.

**Step 3** — run the EMS (same command as the local setup):

```bash
cd examples
python main_mixed.py
```

The EMS uses the exact same config for both local and Docker setups — the serial paths (`/tmp/dertwin_pv_client`, `/tmp/dertwin_meter_client`) are identical. The only difference is how those paths are created: locally via direct socat pairs, or via Docker with TCP bridging.

### Override config at runtime

```bash
docker run \
  -v /path/to/my/configs:/app/configs:ro \
  -e CONFIG_PATH=/app/configs/my_site.json \
  -p 55001:55001 \
  dertwin-simulator
```

---

## 🧪 Tests

```bash
pytest
```

The test suite covers device physics (BESS, PV, CHP, energy meter), solar geometry and clear-sky irradiance against published reference values, cloud-model statistics, the statistics of the stochastic site load, register encoding with per-register endianness, FC02 discrete input routing, external models, protocol parity (TCP and RTU), mixed-protocol engine integration, runtime asset add/remove, and full end-to-end site integration via Modbus. See `tests/` for structure.

The built-in solar model is also cross-checked against `pvlib`, which is
optional, so that suite skips unless you install it:

```bash
pip install "dertwin[pvlib]"
```

---

## 📈 Roadmap

- [ ] Scenario engine — scripted event sequences
- [ ] Markov-regime cloud model as an alternative to AR(1)
- [x] Location- and date-aware clear-sky irradiance with cloud cover
- [x] Plane-of-array irradiance, DC/AC ratio and inverter clipping
- [x] Stochastic site load with daily profile and drift
- [x] Hard BESS SOC limits with optional persistence
- [x] Dynamic asset add/remove at runtime
- [x] CHP support with realistic state machine
- [x] Modbus FC02 discrete input support
- [x] Per-register endianness (big/little)
- [x] Modbus RTU support
- [x] Mixed-protocol sites (TCP + RTU)
- [x] Docker RTU-over-TCP bridging
- [x] Published PyPI package

---

## 🧠 Use Cases

- EMS algorithm development and validation
- SCADA/HMI integration testing
- Protocol compliance testing (TCP and RTU)
- DER fleet orchestration prototyping
- Frequency and voltage response simulation
- Mixed-protocol site simulation
- CHP dispatch and startup-sequence testing against EMS
- Live scenario scripting — bring assets online and offline during a simulation
- EMS-in-the-loop tests where the asset roster is decided by the controller under test

---

## 🤝 Contributing

Contributions are welcome. Before diving in, read [`dertwin/README.md`](dertwin/README.md) — it covers the simulator architecture, how devices are modeled, the engine and clock design, and how to add new device types or protocols.

See [CONTRIBUTING.md](CONTRIBUTING.md) for full guidelines, including how to add new protocols and test RTU without hardware.

---

## 📜 License

MIT License

---

## 👤 Author

Oleksandr Spivak