# comfoconnect-pro-modbus

Read and control Zehnder ComfoAir Q and Flex ventilation units through the ComfoConnect PRO gateway over Modbus TCP or Modbus RTU.

## Installation

```bash
pip install comfoconnect-pro-modbus "modbus-connection[tmodbus]"
```

It needs Python 3.12 or later and [modbus-connection](https://github.com/home-assistant-libs/modbus-connection) 4.12.4 or later. The examples use its tmodbus backend, which `modbus-connection[tmodbus]` installs.

## Device setup

- **Protocol:** select Modbus TCP or Modbus RTU on the gateway's Protocols and services page. The default is none.
- **Connection:** Modbus TCP uses port 502. For Modbus RTU, the baud rate and parity must match the gateway. The default parity is even with 1 stop bit. With no parity, the gateway uses 2 stop bits.
- **Unit ID:** `DEFAULT_UNIT_ID` (1) by default, settable from 1 to 247 on the gateway.
- **Firmware:** the ventilation unit's firmware must be compatible with the gateway. Otherwise `async_detect()` raises `NoVentilationUnitError` with `INCOMPATIBLE_VERSION`.
- **Supported devices:** the ComfoConnect PRO (product number 30006323) with a ComfoAir Q or Flex on ComfoNet. With any other unit, or none, `async_detect()` raises `NoVentilationUnitError`.
- **Network:** for Modbus RTU, wire the gateway's terminals A and B to the RS-485 adapter.

## Usage

The library builds on modbus-connection. You open the connection and pass the library a `ModbusUnit`. The library never opens or closes the connection itself.

```python
import asyncio

from modbus_connection import ModbusTcpParams
from modbus_connection.tmodbus import ModbusConnection

from comfoconnect_pro_modbus import ComfoConnectPro, VentilationPreset


async def main() -> None:
    connection = ModbusConnection(ModbusTcpParams(host="192.168.1.50"))
    try:
        gateway = await ComfoConnectPro.async_detect(connection.for_unit(1))
        await gateway.async_update()

        print("Airflow:", gateway.sensors.airflow, "m³/h")
        print("Outdoor:", gateway.sensors.outdoor_temperature, "°C")
        print("Alarms:", gateway.status.active_alarms)

        await gateway.controls.async_write_ventilation_preset(VentilationPreset.HIGH)
    finally:
        await connection.close()


asyncio.run(main())
```

Over RS-485, pass `ModbusSerialParams` instead:

```python
from modbus_connection import ModbusSerialParams

ModbusSerialParams(device="/dev/ttyUSB0", baudrate=19200, parity="E", stopbits=1)
```

Every value is `None` until the first update. Each update returns an `UpdateReport`. `report.updated` names the components that refreshed. `report.failed` maps the others to their error, and those keep their previous values. A lost connection raises `ModbusConnectionError`.

## Gotchas

- **No identity:** the gateway reports no serial number, model or firmware version.
- **No off switch:** the unit cannot be turned off or put into standby over Modbus.
- **Presets and auto mode:** a preset write alone overrides auto mode for 2 hours, and `auto_mode` stays `True`. The unit then picks the speed again. Write `auto_mode` off first to keep the preset.
- **Away and boost:** both run on top of auto mode or a manual preset. `auto_mode` stays as it was. While away is on, `ventilation_preset` reads `AWAY`. While a boost runs, it reads `HIGH`. When either ends, the unit returns to auto mode or the earlier preset.
- **Temperature profile:** `temperature_profile` applies only in the adaptive and fixed modes. The external setpoint applies only in the external setpoint mode.
- **Comfort temperature:** the external setpoint's register reads back the comfort temperature in effect, in every mode. `comfort_temperature` holds it. A write to `async_write_external_setpoint()` sets the external setpoint, which `comfort_temperature` shows only in the external setpoint mode.
- **Boost time:** the boost time's register reads back the time left on a running boost, and 0 without one. `boost_remaining` holds it. `async_write_boost_time()` sets the length of the next boost, which nothing reads back, so write it before each boost. It takes whole seconds from 0 to 65534, or exactly `BOOST_TIME_MAX` (86400) for 24 hours. Other values raise `InvalidValueError`. Zehnder's app calls the boost the party timer.
- **External setpoint:** takes 0 to 40 °C. The manual gives no range, so the library picks this one.
- **CO₂ zones:** a zone that reads 0 counts as having no sensor.
- **Room sensor:** without a room sensor, both room registers read 0. `room_temperature` and `room_humidity` are then `None`.
- **ComfoCool:** `comfocool` reads `True` on a unit without a ComfoCool. It is a setting, not a sign that one is fitted.
- **Unit-side changes:** the unit changes `boost`, `auto_mode` and `ventilation_preset` itself, for example when a boost ends. Poll `async_update_settings()` as often as the readings if you show them.
- **Write retries:** every write sets an absolute value, so retrying one is safe. A `ModbusTimeoutError` on a write does not mean the gateway ignored it.
- **Stalled link:** a poll can take several request timeouts before it raises.
- **Lost path to the unit:** the gateway can lose its Modbus path to the ventilation unit while Zehnder's app still reaches it. It then refuses every read, the connection state included, with Modbus exception 10 (gateway path unavailable). `async_detect()` raises `NoVentilationUnitError` with `state` `None`. Saving the gateway's settings, which restarts it, did not bring the path back in testing. Power cycling the ventilation unit did.
- **Testing:** built against the gateway's installation manual, document revision 140. Tested on a ComfoConnect PRO with firmware 1.0.5 and a ComfoAir Q, without a room sensor, CO₂ sensors or a ComfoCool.

## API

### `ComfoConnectPro(unit, *, timeout=None)`

The gateway and its ventilation unit, reached through a modbus-connection `ModbusUnit`.

- `await async_detect(unit, *, timeout=None)`: build the device after checking that the gateway reaches a ventilation unit.
- `await async_update_readings()`: read `status` and `sensors`. Returns an `UpdateReport`.
- `await async_update_settings()`: read `controls`. Returns an `UpdateReport`.
- `await async_update()`: read all three in one `UpdateReport`.
- `await async_read_raw()`: every register and bit the device reads, undecoded.
- `status`, `sensors`, `controls`: the components below.

### `status` (`Status`)

- `connection_state`: a `ConnectionState`. `OK` when the gateway reaches a supported unit. `None` for a code the manual does not list.
- `connection_code`: the raw connection state number.
- `is_connected`: whether `connection_state` is `OK`.
- `active_alarms`: the active alarms, as `AlarmCode` members, or plain numbers for codes the manual does not list.
- `active_error_1` to `active_error_5`: the alarm in each slot, as an `AlarmCode` or a plain number, or 0 for an empty slot.
- `active_error(slot)`: the same, by slot number 1 to 5.
- `error_flag`: at least one alarm is active.
- `filter_dirty`: the filters must be replaced.
- `standby`: the unit is in standby.
- `comfohood`: the ComfoHood cooker hood is on.

### `sensors` (`Sensors`)

- `airflow`: the airflow, in m³/h.
- `room_temperature`, `extract_temperature`, `exhaust_temperature`, `outdoor_temperature`, `supply_temperature`: the air temperatures, in °C.
- `room_humidity`, `extract_humidity`, `exhaust_humidity`, `outdoor_humidity`, `supply_humidity`: the air humidities, in %.
  The room values are `None` without a room sensor.
- `co2(zone)`: the CO₂ level in zone 1 to 8, in ppm.
- `co2_zones`: the zones reporting a level, as `{zone: ppm}`.
- `filter_days_remaining`: the time until the filters are due, in days.

### `controls` (`Controls`)

- `ventilation_preset`: the fan speed, a `VentilationPreset`.
- `auto_mode`: the unit picks the speed itself.
- `boost`: the boost is running.
- `boost_remaining`: the time left on a running boost, in seconds, or 0 without one.
- `away_function`: the away function is on. It is separate from `VentilationPreset.AWAY`.
- `comfocool`: ComfoCool may cool.
- `temperature_profile`: a `TemperatureProfile`.
- `temperature_profile_mode`: a `TemperatureProfileMode`.
- `comfort_temperature`: the comfort temperature in effect, in °C. In the external setpoint mode, the external setpoint.
- `await async_write_ventilation_preset(preset)`: set the fan speed.
- `await async_write_auto_mode(on)`: turn auto mode on or off.
- `await async_write_boost(on)`: start or stop a boost.
- `await async_write_boost_time(seconds)`: set how long the next boost lasts, up to `BOOST_TIME_MAX`.
- `await async_write_away_function(on)`: turn the away function on or off.
- `await async_write_comfocool(on)`: allow or stop ComfoCool cooling.
- `await async_write_temperature_profile(profile)`: set the temperature profile.
- `await async_write_temperature_profile_mode(mode)`: set the temperature profile mode.
- `await async_write_external_setpoint(celsius)`: set the external setpoint, which the unit follows in the external setpoint mode.
- `await async_reset_errors()`: clear the alarms.

### Enums

- `VentilationPreset`: `AWAY`, `LOW`, `MEDIUM`, `HIGH`.
- `TemperatureProfile`: `NORMAL`, `COLD`, `WARM`.
- `TemperatureProfileMode`: `ADAPTIVE`, `FIXED`, `EXTERNAL_SETPOINT`.
- `ConnectionState`: `OK`, `NOT_COMFOAIR_Q`, `INCOMPATIBLE_VERSION`, `NO_VENTILATION_UNIT`.
- `AlarmCode`: the 64 ComfoAir Q alarm codes. [`enums.py`](src/comfoconnect_pro_modbus/enums.py) describes each one.

### Errors

All errors the library raises itself derive from `ComfoConnectProError`. Transport and device errors come from modbus-connection.

- `NoVentilationUnitError`: raised by `async_detect()` when the gateway reports a connection state other than `OK`, or has no path to the unit. Its `state` holds the `ConnectionState`, or `None` for a code the manual does not list or no code at all. Its `code` holds the raw number.
- `InvalidValueError`: raised by a write before anything is sent, for a value the gateway cannot take: a boost time it cannot store, an external setpoint outside 0 to 40 °C, a value that is not a member of the field's enum, or a switch value that is not a `bool`. `active_error()` and `co2()` raise it for a slot or zone out of range. It is also a `ValueError`.
- `ModbusConnectionError` (modbus-connection): the link to the gateway is lost.
- `ModbusTimeoutError` (modbus-connection): the gateway did not answer in time. An update raises it when the first component it reads times out. A later timeout lands in `report.failed`.
- `ModbusExceptionError` (modbus-connection): the gateway refused a read or a write. A refused read during an update lands in `report.failed`.

The register addresses are in the component modules under [`src/comfoconnect_pro_modbus`](src/comfoconnect_pro_modbus), and in chapter 9.3 of the gateway's installation manual.

## Troubleshooting

`script/query.py` reads the device once and prints every value:

```bash
uv run script/query.py 192.168.1.50
uv run script/query.py /dev/ttyUSB0 --baudrate 19200 --parity E
```

Add `--raw` to include the undecoded registers. A bug report about a wrong value needs them.

If every read fails with "the gateway has no path to the ventilation unit" while Zehnder's app still works, power cycle the ventilation unit. See **Lost path to the unit** under Gotchas.

The `comfoconnect_pro_modbus` logger reports at `DEBUG` the connection state `async_detect()` found and each component that failed to refresh during an update.