Metadata-Version: 2.5
Name: fieldsim
Version: 0.3.0
Summary: Virtual Modbus, OPC UA and S7 devices for testing industrial software without hardware.
Project-URL: Homepage, https://github.com/enesuslu15/fieldsim
Project-URL: Issues, https://github.com/enesuslu15/fieldsim/issues
Author: enesuslu15
License: MIT License
        
        Copyright (c) 2026 enesuslu15
        
        Permission is hereby granted, free of charge, to any person obtaining a copy
        of this software and associated documentation files (the "Software"), to deal
        in the Software without restriction, including without limitation the rights
        to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
        copies of the Software, and to permit persons to whom the Software is
        furnished to do so, subject to the following conditions:
        
        The above copyright notice and this permission notice shall be included in all
        copies or substantial portions of the Software.
        
        THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
        IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
        FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
        AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
        LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
        OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
        SOFTWARE.
License-File: LICENSE
Keywords: iiot,industrial,modbus,opc-ua,plc,pytest,s7,simulator,testing
Classifier: Development Status :: 3 - Alpha
Classifier: Framework :: AsyncIO
Classifier: Framework :: Pytest
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: Manufacturing
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Topic :: Software Development :: Testing
Classifier: Topic :: System :: Networking
Classifier: Typing :: Typed
Requires-Python: >=3.10
Requires-Dist: pydantic<3,>=2.6
Requires-Dist: pyyaml>=6.0
Requires-Dist: typer>=0.12
Provides-Extra: dev
Requires-Dist: asyncua<3,>=2.1; extra == 'dev'
Requires-Dist: mypy>=1.10; extra == 'dev'
Requires-Dist: pre-commit>=3.5; extra == 'dev'
Requires-Dist: pymodbus<4,>=3.10; extra == 'dev'
Requires-Dist: pytest-asyncio>=0.23; extra == 'dev'
Requires-Dist: pytest-cov>=5.0; extra == 'dev'
Requires-Dist: pytest>=8.0; extra == 'dev'
Requires-Dist: ruff>=0.6; extra == 'dev'
Requires-Dist: types-pyyaml; extra == 'dev'
Provides-Extra: opcua
Requires-Dist: asyncua<3,>=2.1; extra == 'opcua'
Description-Content-Type: text/markdown

# fieldsim

**Virtual industrial devices for testing software without hardware.**

fieldsim starts fake Modbus and OPC UA devices (S7 is on the roadmap) from a YAML
file, drives their values with generators, breaks them on purpose with fault
injection and plays scripted scenarios — so you can test gateways, SCADA
connectors and edge apps in CI, no PLC on your desk required.

> Status: alpha (`0.3.0`). The file format may still change before 1.0.

## Install

```bash
pip install fieldsim             # Modbus TCP / RTU over TCP
pip install "fieldsim[opcua]"    # + OPC UA (uses asyncua)
```

or run it as a container:

```bash
docker run --rm -p 5020:5020 -v "$PWD/boiler.yaml:/config/devices.yaml:ro" ghcr.io/enesuslu15/fieldsim
```

## Test with pytest

Installing fieldsim registers a pytest plugin. With no configuration at all you
get a Modbus TCP device whose whole address space is plain memory:

```python
def test_gateway_writes_registers(modbus_device):
    Gateway(modbus_device.host, modbus_device.port).write_register(100, 42)
    event = modbus_device.wait_for_write(timeout=2)
    assert event.address == 100 and event.values == (42,)
```

Point it at a device file to get named points, generators and scenarios:

```python
import pytest


@pytest.mark.fieldsim("boiler.yaml")
def test_gateway_reads_temperature(modbus_device):
    modbus_device.set("temperature", 85.0)  # pauses the generator
    assert Gateway(*modbus_device.address).temperature() == 85.0


@pytest.mark.fieldsim("boiler.yaml")
def test_gateway_survives_a_slow_plc(modbus_device):
    with modbus_device.fault("latency", delay="800ms"):
        assert Gateway(*modbus_device.address, timeout=1).temperature() is not None


@pytest.mark.fieldsim("boiler.yaml")
def test_gateway_retries_lost_responses(modbus_device):
    with modbus_device.fault("drop", count=2) as fault:
        Gateway(*modbus_device.address, retries=3).temperature()
    assert fault.hits == 2


@pytest.mark.fieldsim("boiler.yaml")
def test_gateway_reconnects_after_outage(modbus_device):
    gw = Gateway(*modbus_device.address)
    with modbus_device.offline():
        assert not gw.healthy()
    assert gw.healthy()


@pytest.mark.fieldsim("boiler.yaml")
def test_gateway_writes_setpoint(modbus_device):
    Gateway(*modbus_device.address).set_setpoint(80)
    modbus_device.wait_for_write("setpoint", timeout=2)
    assert modbus_device.get("setpoint") == 80


@pytest.mark.fieldsim("boiler.yaml", clock="virtual")
def test_overheat_alarm(modbus_device):
    modbus_device.advance(600)  # ten minutes, instantly
    ...
```

OPC UA works the same way:

```python
@pytest.mark.fieldsim("packaging_line.yaml")
async def test_reads_speed(opcua_device):
    opcua_device.set("Line1.Speed", 1.05)
    async with Client(opcua_device.endpoint) as client:
        assert await client.get_node(opcua_device.node_id("Line1.Speed")).read_value() == 1.05


@pytest.mark.fieldsim("packaging_line.yaml")
async def test_reports_timeouts(opcua_device):
    with opcua_device.fault("status", code="BadTimeout", services=["Read"]):
        ...
```

Fixtures and options:

| | |
|---|---|
| `modbus_device`, `opcua_device` | The Modbus / OPC UA device of the simulation (choose with `mark.fieldsim(device="name")` if there are several). |
| `fieldsim` | The whole running simulation: `fieldsim["plc-1"]`, `fieldsim.advance(10)`. |
| `make_modbus_device`, `make_opcua_device` | Factories for ad-hoc devices: `make_modbus_device(registers={...}, unit_id=3)`. |
| `@pytest.mark.fieldsim(config, device=, clock=, free_ports=)` | Per-test configuration. `config` is a YAML path (relative to the test file or rootdir) or a dict. |
| ini `fieldsim_config`, `fieldsim_clock`, `fieldsim_free_ports` | Project-wide defaults. |

Devices run in a background thread on free ports, so the fixtures work in plain,
asyncio and trio tests, and with `pytest-xdist`. In async tests use
`await device.wait_for_write_async(...)` and `await device.advance_async(...)`.

## Describe a device

```yaml
# boiler.yaml
version: 1
devices:
  - name: boiler-plc
    protocol: modbus_tcp          # or modbus_rtu_over_tcp
    port: 5020
    registers:
      coils:
        - { name: pump_on, address: 0, value: true }
      holding_registers:
        - name: temperature
          address: 0
          type: float32
          generator: { type: sine, min: 60, max: 90, period: 30s }
        - { name: setpoint, address: 2, type: uint16, value: 75 }

    faults:                       # active from the start
      - { type: latency, delay: 20ms, jitter: 10ms }

    scenario:                     # relative to device start
      - { at: 30s, set: { temperature: 120 } }
      - { at: 40s, fault: { type: exception, code: 6 }, duration: 5s }
      - { at: 60s, offline: 10s }
      - { at: 90s, release: [temperature] }
```

An OPC UA device is a tree of folders and variables; a variable's point name is
its dotted path and its node id `ns=<index>;s=<path>` unless you set `node_id`:

```yaml
  - name: packaging-line
    protocol: opcua
    port: 4840                    # endpoint opc.tcp://127.0.0.1:4840/
    nodes:
      - name: Line1
        nodes:
          - { name: Speed, type: Double, generator: { type: sine, min: 0.8, max: 1.2, period: 20s } }
          - { name: Setpoint, type: Int32, value: 120, writable: true }
          - { name: Product, type: String, value: A-100, writable: true, node_id: "i=1001" }
    scenario:
      - { at: 40s, fault: { type: status, code: BadTimeout, services: [Read] }, duration: 5s }
```

Variable types: `Boolean SByte Byte Int16 UInt16 Int32 UInt32 Int64 UInt64 Float Double String`.
Values set from code or written by clients are pushed to subscriptions.

## Command line

```bash
fieldsim init plant.yaml --protocol opcua   # starter file (modbus or opcua)
fieldsim validate plant.yaml                # check without starting
fieldsim run plant.yaml --host 0.0.0.0      # serve until Ctrl+C (--duration N to stop)
fieldsim check plant.yaml --wait 30         # exit 0 once every device accepts connections
fieldsim schema -o fieldsim.schema.json     # JSON Schema for editor autocompletion
```

## Docker and CI

The image `ghcr.io/enesuslu15/fieldsim` (amd64, arm64) runs
`fieldsim run /config/devices.yaml --host 0.0.0.0` and has a health check, so
other services can wait for it with `depends_on: {condition: service_healthy}`.
See [`examples/docker-compose.yml`](examples/docker-compose.yml) and, for GitHub
Actions with either the pytest plugin or the container,
[`examples/github-actions.yml`](examples/github-actions.yml).

### Device options

| Key | Meaning |
|---|---|
| `protocol` | `modbus_tcp`, `modbus_rtu_over_tcp` (RTU frames with CRC tunnelled over TCP) or `opcua`. |
| `host`, `port` | Listen address. `port: 0` picks a free port. |
| `unit_id` | Modbus: only answer this unit id (default: answer all). |
| `unmapped` | Modbus: `error` (exception 02 for undefined addresses, default) or `allow` (plain memory). |
| `path`, `namespace` | OPC UA: endpoint URL path (default `/`) and namespace URI. |
| `update_interval` | Generator refresh rate, e.g. `100ms`. |
| `faults` | Faults active from the start (see below). |
| `scenario` | Timed steps: `set`, `release`, `fault` (+ `duration`), `offline`. |
| `seed` | Makes random faults reproducible. |

Points live in `registers.coils`, `discrete_inputs`, `holding_registers` and
`input_registers`, with `name`, `address`, `value`, `generator`, `description` and —
for registers — `type` (`int16 uint16 int32 uint32 int64 uint64 float32 float64`),
`byte_order` and `word_order`. Coils and holding registers take `writable: false`.

Generators: `constant`, `sine`, `ramp` (`sawtooth` / `triangle` / `once`),
`random_walk`, `sequence`.

### Faults

| Type | Effect |
|---|---|
| `latency` | Delay responses by `delay` + random `0..jitter`. |
| `drop` | No response. `executed: true` still performs the request (lost reply). |
| `disconnect` | Close the connection instead of answering. |
| `exception` | Modbus: answer with exception `code` (default 6, SERVER DEVICE BUSY). |
| `status` | OPC UA: answer with a ServiceFault carrying `code` (e.g. `BadTimeout`). |
| `corrupt` | Damage the response: `bit_flip`, `truncate`, `garbage`, `bad_length` (Modbus TCP, OPC UA), `transaction_id` (Modbus TCP), `bad_crc` (Modbus RTU). |

Every fault accepts `probability` (0..1), `count` (remove after N hits) and a
filter: `function_codes` for Modbus, `services` (`Read`, `Write`, `Browse`,
`Publish`, ...) for OPC UA.

OPC UA faults are applied by a small proxy in front of the server that matches
responses to requests and renumbers the secure channel's sequence numbers, so a
dropped or injected message never breaks the session by itself.

## Use from Python

```python
from fieldsim import Simulator, VirtualClock

clock = VirtualClock()
async with Simulator.from_yaml("boiler.yaml", clock=clock) as sim:
    plc = sim["boiler-plc"]
    with plc.fault("corrupt", mode="bit_flip", probability=0.1):
        await clock.advance(60)
```

From synchronous code use `BackgroundSimulator("boiler.yaml")` as a context
manager; its device handles are thread-safe.

## Supported Modbus function codes

01 Read Coils · 02 Read Discrete Inputs · 03 Read Holding Registers · 04 Read Input Registers ·
05 Write Single Coil · 06 Write Single Register · 15 Write Multiple Coils · 16 Write Multiple Registers

## Development

```bash
python -m venv .venv
.venv/Scripts/activate        # Windows; use .venv/bin/activate elsewhere
pip install -e ".[dev]"
pre-commit install
coverage run -m pytest && coverage report
```

`coverage run` is used instead of `pytest --cov` because fieldsim's own pytest
plugin is imported before pytest-cov starts measuring.

## License

MIT