{
    "DeviceClass": "aa148d2e-6e09-453e-bc6f-63baa5f5ccc4", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "System BIOS - A66", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "A66_1.22_08_08_2025.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000284", 
                "Version": "v1.22 (08/08/2025)"
            }, 
            {
                "DeviceName": "System BIOS - A66", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "A66_1.22_08_08_2025.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000285", 
                "Version": "v1.22 (08/08/2025)"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "BIOS - System ROM"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "67116427", 
                "DateModified": "2025-08-12T02:14:08", 
                "FileList": [
                    "A66_1.22_08_08_2025.signed.flash"
                ], 
                "MD5Sum": "0b7f1d7cf47e5e0d9000aa2435dae3e6", 
                "Name": "A66_1.22_08_08_2025.fwpkg", 
                "Release": "2025-08-12T02:10:40", 
                "Revision": "", 
                "SHA1Sum": "07536b56f8a26f09a12fd71b49961d6d7bf7b9d1", 
                "SHA256Sum": "41ffc5c4df39788904cda1ded4238b509e1f262475df7097a025683a48c89388", 
                "Size": "64.01MB", 
                "TargetGUIDs": [
                    "00000000-0000-0000-0000-000000000284", 
                    "00000000-0000-0000-0000-000000000285"
                ], 
                "TypeOfChange": "1", 
                "Version": "1.22_08-08-2025"
            }
        ], 
        "Id": {
            "Product": "ce8b7e2d14a74bb5815bd807cefd3dc0", 
            "Version": "36f14642f0a24b47a21310d307109931"
        }, 
        "Installation": {
            "Command": "cpqsetup.exe", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "yes"
            }, 
            "PerDeviceInstallTimeSeconds": 300, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "yes", 
            "RebootRequirement": "Required"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO7_IP_Address&gt; -u &lt;iLO7_username&gt; -p &lt;iLO7_password&gt;</em></strong></p>\n\n<p>Place the json file in the same folder as the fwpkg file.<br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL345 Gen12 (A66) Servers"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "11000"
            }, 
            "SupportedDevices": [], 
            "SupportedOperatingSystems": [
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 9.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2025-09-11T06:28:31", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "", 
                        "Fixes": "<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p>\n<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Attribute Names in BIOS Attribute Registry is not aligned with BIOS Settings URI.</p><p>Addressed an issue where the DisplayName of AllowLoginWithIlo attribute in BIOS registry showed incorrectly. </p><p>Addressed an issue where the second firmare information in RBSU may show \"Unknown\" for Intel E610/E810 NIC card.</p><p>Corrected the USB numbering on the media bay. </p><p>Addressed an issue where sending a GET request on /redfish/v1/ComponentIntegrity/HardwareDataBlob resulted in an error of messageId SystemResetRequired.</p><p>Addressed an issue where BIOS settings may not be applied while upgrading BIOS and changing BIOS settings at the same time. </p><p>Addressed an issue where the SMBIOS Type9 information was not correct for empty OCP slots.</p><p>Addressed an issue where the IML for DIMM mapped out may not be logged.</p><p>Addressed an issue where SaveUserDefaults in Redfish baseconfigs still showed \"Yes\" after saving Settings and Reboot.</p><p>Addressed an issue where the PCIe Riser MCU firmware information may not display correctly.</p><p>Addressed an issue where incorrect Structure Boot Name may show in the OS boot option.</p><p>Addressed an issue where the information for PCIe Slot3 and Slot4 was swapped. </p><p>Addressed an issue where the Server Name may display incorrectly in iLO web.</p><p><strong>Known Issues:</strong></p>None", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.22_08-08-2025"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>Reassigned the NIC port number by MAC order when the slot is set to bifurcated.</p>", 
                        "Fixes": "<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code TurinPI 1.0.0.6 for AMD 5th Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p>\n<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where disabled USB ports may still show on the One-Time Boot Menu.</p><p>Addressed an issue where the SMBIOS information for PCIe Risers may be incorrect.</p><p>Addressed an issue where the Host Health LED would not turn on \"Warning\" when a fatal error was detected.</p><p>Addressed an issue where system may hang when Microsoft secure-core support is enabled. </p><p>Addressed an issue where system may show incorrect firmware version for CX8-AUX card in RBSU. </p><p>Addressed an issue where the Correct IPMI action type may be incorrect.</p><p>Addressed an issue where the system may encounter Uncorrectable Machine Check Exception when USB mouse is moving while entering RBSU.</p><p>Addressed an issue where the Network Boot Retry Count in RBSU\\Network Boot Options would not work.</p><p><strong>Known Issues:</strong></p>None", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.20_07-11-2025"
            }
        ], 
        "SWKeys": [
            {
                "Name": "A66", 
                "SWKeyExpectedPath": "firmware:system"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL325 Gen12 Server"
            }, 
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL345 Gen12 Server"
            }, 
            {
                "Family": "FTP", 
                "Model": "FTP-Only System"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "ComboFirmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}