    "DeviceClass": "79f0c163-0c13-4662-9dea-09235fef90cb", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "HPE_MR416i-a_Gen10p", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "HPE_MR416i-a_Gen10P_52.36.3-6584_A.HPb", 
                        "InstallDurationSec": 360, 
                        "Order": 1, 
                        "PLDMImage": true, 
                        "ResetRequired": false, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": true, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "a6b1a447-382a-5a4f-1000-10e21590032a", 
                "Version": "52.36.3-6584"
            }
        ]
    }, 
    "MinimumActiveVersion": "52.26.3.5487", 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "Firmware - Storage Controller"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Storage"
                    }
                ]
            }, 
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "7517135", 
                "DateModified": "2026-03-04T18:10:19", 
                "FileList": [
                    "HPE_MR416i-a_Gen10P_52.36.3-6584_A.HPb", 
                    "HPE_MR416i-a_Gen10P_52.36.3-6584_A.xml", 
                    "payload.json"
                ], 
                "MD5Sum": "92f9a74bcb65c86c6270b0503b8913ed", 
                "Name": "HPE_MR416i-a_Gen10P_52.36.3-6584_A.fwpkg", 
                "Release": "2026-03-04T18:05:40", 
                "Revision": "", 
                "SHA1Sum": "d82f0b1c0d0ff09604de03c648599810e3e833b2", 
                "SHA256Sum": "65343e88e1679b2d6e77123e41d9c841ba4fa098391ef56853e35ff836eee02b", 
                "Size": "7.17MB", 
                "TargetGUIDs": [
                    "a6b1a447-382a-5a4f-1000-10e21590032a"
                ], 
                "TypeOfChange": "1", 
                "Version": "52.36.3-6584"
            }
        ], 
        "Id": {
            "Product": "c9a4232d8cb349049f544bcc6d02e97f", 
            "Version": "67690d6d946c40fa82f4658bcf5a763e"
        }, 
        "Installation": {
            "Command": "", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "no"
            }, 
            "PerDeviceInstallTimeSeconds": 360, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is not required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "no", 
            "RebootRequirement": "No"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">RESTful Interface Tool</a><a href=\"http://www.hpe.com/servers/resttool\">l</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n\n<p>Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n</ul>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "32000"
            }, 
            "SupportedDevices": [
                {
                    "Dev": "10E2", 
                    "SubDev": "032A", 
                    "SubVen": "1590", 
                    "TargetGUID": "a6b1a447-382a-5a4f-1000-10e21590032a", 
                    "Type": "pci", 
                    "Ven": "1000"
                }
            ], 
            "SupportedOperatingSystems": [
                {
                    "Major": "7", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 7.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "18999", 
                    "Minimumbuild": "17600", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2019", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "17599", 
                    "Minimumbuild": "14393", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2016", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 8 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "15", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 15", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "25398", 
                    "Minimumbuild": "20317", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2022", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 9 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 8.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minimumbuild": "25399", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2025", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 9.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2025-10-17T14:32:40", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<ul>\n\t<li>7.36 Aero PR11 GCA</li>\n</ul>\n", 
                        "Fixes": "", 
                        "Lang": "en"
                    }
                ], 
                "Version": "52.36.3-6584"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<ul>\n\t<li>DMTF PLDM Redfish Device Enablement enhancements\n\t<ul>\n\t\t<li>Redfish Volume Transformation Support\n\t\t<ul>\n\t\t\t<li>POST #Volume.ChangeRAIDLayout: RAID Layout Change. Change in the RAID Layout is achieved by providing the target RAIDType and the list of the drives in the input JSON body.</li>\n\t\t\t<li>POST #Volume.ChangeRAIDLayout: Resize. ChangeRAIDLayout can be used to resize the volume by adding new Unconfigured Good drives without changing the RAIDType. In such cases RAIDType must not be provided in the input JSON body but the full drive list must be provided accordingly.</li>\n\t\t\t<li>PATCH Volume[CapacityBytes]: This operation is used for resizing the volume when there is unused size available in the volume. There is no scope for adding any new drives here</li>\n\t\t\t<li>POST #Volume.CheckConsistency: This operation starts Consistency Check operation on the volume. No input is expected for this operation.</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Redfish Metrics GET Support\n\t\t<ul>\n\t\t\t<li>StorageControllerMetrics: UncorrectableECCErrorCount, CorrectableECCErrorCount, CorrectableParityErrorCount, StateChangeCount</li>\n\t\t\t<li>PortMetrics: SAS.InvalidDwordCount, SAS.LossOfDwordSynchronizationCount, SAS.RunningDisparityErrorCount, PCIeErrors.CorrectableErrorCount, PCIeErrors.FatalErrorCount, PCIeErrors.NonFatalErrorCount</li>\n\t\t\t<li>Each counter can hold a value up to 65535. Once the counter reaches the maximum value the value is not reset.</li>\n\t\t\t<li>Metrics are cleared when user performs Controller NVRAM clear or Redfish ResetToDefaults.ResetAll.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Add support for users to clear NVRAM using MRSA and storcli Factory Repurpose operation.\n\t<ul>\n\t\t<li>Clear NVRAM operation is not allowed if there is any configuration present on the controller or if there is any pinned cache.</li>\n\t\t<li>After clearing NVRAM, controller FW performs Online Controller Reset (OCR). If for some reason OCR cannot be performed, then the user will be notified to perform a system reboot.</li>\n\t\t<li>The Clear NVRAM operation is equivalent to Redfish ResetToDefaults.ResetAll operation functionally.</li>\n\t</ul>\n\t</li>\n\t<li>Change the backplane bay count information to the actual bay that is connected to controller. For non-hotplug configuration, controller always shows 16 bays.</li>\n</ul>\n", 
                        "Fixes": "<ul>\n\t<li>Fix a00143124en_us Advisory: HPE MR Gen11 Controller - MR Gen11 Controllers on HPE Gen11 Servers May Fail to Generate &quot;WriteCacheDataLoss&quot; in the IML</li>\n\t<li>Fix a00148035en_us Advisory: HPE MR Gen11 Controllers - The Bay And Box NVMe Drive Location Is Not Displayed in the One-Time Boot Menu</li>\n\t<li>Fix an issue that Read/Write transfers over 128KB on LTO fail in Linux OS</li>\n\t<li>Fix an issue that Backup Exec doesn&rsquo;t work with LTO</li>\n\t<li>Fix an issue that controller might be dropped by the iLO in server boot up when there are 240 Logical Drives are configured</li>\n\t<li>Fix a rare issue that server health shows critical temporally when remove drive continuously.</li>\n\t<li>Fix an issue that unexpected PCIConfiglink page events, Task management to the virtual SES device time out messages are logged in snapdump</li>\n\t<li>Fix an issue that Slot capable protocol is missing for empty bay</li>\n\t<li>Fix an issue that Link Speed for LTO connected to controller shows Unknown</li>\n\t<li>Fix an issue that Request Sense command causes task management on the drive where sanitization is in progress.</li>\n\t<li>Fix an issue that Redfish PATCH StorageController[ControllerRates] silently sets random values when the value beyond 255 is used.</li>\n\t<li>Fix an issue that incorrect controller error event may be logged when controller is configured as passthrough and do vm reboot</li>\n\t<li>Fix an issue that active width, current speed are wrong in Redfish Fabric port when two backplanes connected to same storage port.</li>\n\t<li>Fix a rare issue that NVMe drive link status may fail after reboot&nbsp;</li>\n\t<li>Fix a rare issue that controller may assert when there are multiple drives removed and inserted in a short time</li>\n\t<li>Fix an issue that sanitize percentage does not progress on SATA drives if there is SATA passthrough command running</li>\n\t<li>Fix an issue that sanitize percentage does not progress on NVMe drives</li>\n\t<li>Fix a rare issue that IO timeout and device reset may occur with stress test of Read/Write and Non-Read/Write commands</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "52.32.3-6333"
            }
        ], 
        "SWKeys": [
            {
                "Name": "032A1590", 
                "SWKeyExpectedPath": "firmware"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U46", 
                "Model": "HPE ProLiant with vSphere Distributed Services Engine"
            }, 
            {
                "Family": "A43", 
                "Model": "HPE ProLiant DL325 Gen10 Plus v2 Server"
            }, 
            {
                "Family": "A43", 
                "Model": "HPE ProLiant DL345 Gen10 Plus Server"
            }, 
            {
                "Family": "A42", 
                "Model": "HPE ProLiant DL385 Gen10 Plus v2 Server"
            }, 
            {
                "Family": "A42", 
                "Model": "HPE ProLiant DL365 Gen10 Plus Server"
            }, 
            {
                "Family": "A59", 
                "Model": "HPE ProLiant Compute XD685"
            }, 
            {
                "Family": "U46", 
                "Model": "HPE ProLiant DL380 Gen10 Plus Server"
            }, 
            {
                "Family": "U46", 
                "Model": "HPE ProLiant DL360 Gen10 Plus Server"
            }, 
            {
                "Family": "U61", 
                "Model": "HPE ProLiant ML30 Gen10 Plus Server"
            }, 
            {
                "Family": "U60", 
                "Model": "HPE ProLiant DL20 Gen10 Plus Server"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "Firmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}